Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation

被引:56
作者
Eroglu, AE
McLeod, CW [1 ]
Leonard, KS
McCubbin, D
机构
[1] Univ Sheffield, Ctr Analyt Sci, Sheffield S3 7HF, S Yorkshire, England
[2] Ctr Environm Fisheries & Aquaculture Sci, Lowestoft Lab, Lowestoft NR33 0HT, Suffolk, England
关键词
plutonium; seawater; inductively coupled plasma-mass spectrometry (ICP-MS); flow injection; ultrasonic nebulisation;
D O I
10.1016/S0584-8547(98)00179-7
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A flow injection-inductively coupled plasma-mass spectrometric (FI-ICP-MS) procedure, utilising ultrasonic nebulisation with membrane desolvation (USN/MD), has been developed for the determination of plutonium (Pu) in seawater at fg l(-1) concentration levels: Seawater samples (11), after filtration, were subjected to co-precipitation with NdF3, followed by ion exchange to enrich Pu and to reject seawater matrix ions and co-existing uranium. The seawater concentrate (1.0 ml) was then analysed by FI-ICP-MS. The limit of detection for Pu-239 in seawater based on an enrichment factor of 1000 was 5 fg l(-1), and precision at the 0.80 pg l(-1) level was 12% RSD. Accuracy was verified via recovery experiments, and by comparing survey data for the Irish Sea with that derived by standard methodology based on co-precipitation and ol-spectrometry. Concentrations for dissolved Pu-239 and Pu-240 in the Irish Sea were in the range of 0.267-0.941 pg l(-1) (0.614-2.164 mBq l(-1)) and 0.0510.196 pg l(-1) (0.428-1.646 mBq l(-1)), respectively. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1221 / 1233
页数:13
相关论文
共 29 条
[1]  
BOWEN VT, 1971, J MAR RES, V29, P1
[2]   THE MASS-SPECTROMETRIC DETERMINATION OF FALLOUT PU-239 AND PU-240 IN MARINE SAMPLES [J].
BUESSELER, KO ;
HALVERSON, JE .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1987, 5 (06) :425-444
[3]   Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogram range [J].
Chiappini, R ;
Taillade, JM ;
Brebion, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :497-503
[4]   HYDRIDE INTERFERENCE ON THE DETERMINATION OF MINOR ACTINIDE ISOTOPES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CRAIN, JS ;
ALVARADO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1223-1227
[5]  
GREENFIELD S, 1992, INDUCTIVELY COUPLED, pCH4
[6]  
GUSTAVSSON AGT, 1992, INDUCTIVELY COUPLED, pCH15
[7]   EVALUATION OF METHODS FOR THE ASSAY OF NEPTUNIUM AND OTHER LONG-LIVED ACTINIDES IN ENVIRONMENTAL MATRICES [J].
HURSTHOUSE, AS ;
BAXTER, MS ;
MCKAY, K ;
LIVENS, FR .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 157 (02) :281-294
[8]   APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES IN ENVIRONMENTAL-SAMPLES - A REVIEW [J].
IGARASHI, Y ;
KIM, CK ;
TAKAKU, Y ;
SHIRAISHI, K ;
YAMAMOTO, M ;
IKEDA, N .
ANALYTICAL SCIENCES, 1990, 6 (02) :157-164
[9]   The measurement of the isotopic composition of plutonium in an Irish Sea sediment by mass spectrometry [J].
Kershaw, PJ ;
Sampson, KE ;
McCarthy, W ;
Scott, RD .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 198 (01) :113-124
[10]  
KERSHAW PJ, 1992, 32 MIN AGR FISH FOOD