A validation study on the intraobserver and interobserver reproducibility of renal artery duplex ultrasound

被引:24
作者
Baumgartner, I [1 ]
Behrendt, P [1 ]
Rohner, P [1 ]
Baumgartner, RW [1 ]
机构
[1] Univ Bern, Inselspital, Dept Med, Div Angiol, CH-3010 Bern, Switzerland
关键词
duplex ultrasound; renal artery stenosis; Doppler velocimetry;
D O I
10.1016/S0301-5629(98)00142-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim of the present study was to evaluate intraobserver and interobserver reproducibility of direct renal artery Doppler velocimetry. Healthy volunteers were evaluated by one examiner on three separate occasions and by three different examiners in a single day. Peak systolic velocities of the aorta (PSV.Ao) and proximal renal arteries (PSV.RA) were taken at an optimal angle below 60 degrees. The renal-to-aortic ratio (RAR) was calculated dividing PSV.RA by PSV.Ao. Mean values +/-2 SD were 85 +/- 34 (49-150) cm/s for the PSV.RA, 38 +/- 20 (0-60 degrees) for the Doppler angle of insonation, 102 +/- 37 (63-153) cm/s for the PSV/Ao, and 0.85 +/- 0.41 (0.49-1.58) for the RAR. Correlation coefficients and coefficient of variation were 0.64-0.82/7.8%-10.1% (PSV.RA), 0.75-0.82/9.9%-13.8% (RAR) for intraobserver evaluations; and 0.79-0.80/7.7%-12.5% (PSV-RA), 0.65- 0.78/9.5%-12.3% (RAR) for interobserver evaluations. Reliable results of direct renal artery Doppler velocimetry confirm clinical applicability and suitability for repeated measurements after catheter-based interventions or surveillance of low-grade stenoses, (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 18 条
[1]   NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY [J].
AVASTHI, PS ;
VOYLES, WF ;
GREENE, ER .
KIDNEY INTERNATIONAL, 1984, 25 (05) :824-829
[2]   Patency of percutaneous transluminal renal angioplasty: A prospective sonographic study [J].
Baumgartner, I ;
Triller, J ;
Mahler, F .
KIDNEY INTERNATIONAL, 1997, 51 (03) :798-803
[3]   RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS [J].
BERLAND, LL ;
KOSLIN, DB ;
ROUTH, WD ;
KELLER, FS .
RADIOLOGY, 1990, 174 (02) :421-423
[4]   Treatment of ostial renal-artery stenoses with vascular endoprostheses after unsuccessful balloon angioplasty [J].
Blum, U ;
Krumme, B ;
Flugel, P ;
Gabelmann, A ;
Lehnert, T ;
BuitragoTellez, C ;
Schollmeyer, P ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (07) :459-465
[5]   RENAL-ARTERY STENOSIS - EVALUATION WITH COLOR DOPPLER FLOW IMAGING [J].
DESBERG, AL ;
PAUSHTER, DM ;
LAMMERT, GK ;
HALE, JC ;
TROY, RB ;
NOVICK, AC ;
NALLY, JV ;
WELTEVREDEN, AM .
RADIOLOGY, 1990, 177 (03) :749-753
[6]   NONINVASIVE DOPPLER ASSESSMENT OF RENAL-ARTERY STENOSIS AND HEMODYNAMICS [J].
GREENE, ER ;
AVASTHI, PS ;
HODGES, JW .
JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (09) :653-659
[7]   RENAL DUPLEX SONOGRAPHY - EVALUATION OF CLINICAL UTILITY [J].
HANSEN, KJ ;
TRIBBLE, RW ;
REAVIS, SW ;
CANZANELLO, VJ ;
CRAVEN, TE ;
PLONK, GW ;
DEAN, RH .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) :227-236
[8]   ROLE OF DUPLEX SCANNING FOR THE DETECTION OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE [J].
HOFFMANN, U ;
EDWARDS, JM ;
CARTER, S ;
GOLDMAN, ML ;
HARLEY, JD ;
ZACCARDI, MJ ;
STRANDNESS, DE .
KIDNEY INTERNATIONAL, 1991, 39 (06) :1232-1239
[9]   Renal resistive indexes: Variability in Doppler US measurement in a healthy population [J].
Keogan, MT ;
Kliewer, MA ;
Hertzberg, BS ;
DeLong, DM ;
Tupler, RH ;
Carroll, BA .
RADIOLOGY, 1996, 199 (01) :165-169
[10]   Early systole in the healthy kidney: Variability of Doppler US waveform parameters [J].
Kliewer, MA ;
Hertzberg, BS ;
Keogan, MT ;
Paulson, EK ;
Freed, KS ;
DeLong, DM ;
Carroll, BA .
RADIOLOGY, 1997, 205 (01) :109-113