Real-time perfusion imaging: A new echocardiographic technique for simultaneous evaluation of myocardial perfusion and contraction

被引:21
作者
Sieswerda, GT
Yang, L
Boo, MBD
Kamp, O
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Cardiol, NL-1007 MB Amsterdam, Netherlands
[2] Sun Yat Sen Univ, Affiliated Hosp 2, Dept Cardiol, Guangzhou, Peoples R China
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2003年 / 20卷 / 06期
关键词
contrast echocardiography; myocardial perfusion; power pulse inversion imaging; coronary artery disease;
D O I
10.1046/j.1540-8175.2003.03093.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial contrast echocardiogrophy (MCE) with high acoustic energy and triggered harmonic imaging is the best established ultrasound technique to date for the assessment of myocardial perfusion. With this technique, however, the ultimate goal of MCE (noninvasive real-time simultaneous assessment of myocardial perfusion and function after an intravenous injection of microbubbles) is not met. Recently, technologic advances have enabled myocardial opacification to be visualized during low-energy real-time imaging. During real-time perfusion imaging, wall motion and myocardial perfusion may be assessed simultaneously, obviating the need of the presently time-consuming combination of different imaging modalities. When high-energy ultrasound bursts are periodically transmitted to produce bubble destruction during low-power imaging, the consecutive frames after destruction delineate the restoration of contrast intensity. Microbubble replenishment rate and peak intensity may be determined subsequently, and provide reliable quantitative parameters of regional microcirculatory flow. This review will introduce the modalities used for real-time perfusion imaging with focus on power pulse inversion imaging and quantitative analysis. Furthermore, we will describe the clinical role the technique may have in the identification of coronary artery disease, quantification of coronary stenosis severity, assessment of myocardial viability, determination of infarction size, and evaluation of reflow and no- or low-reflow after acute myocardial infarction.
引用
收藏
页码:545 / 555
页数:11
相关论文
共 46 条
[1]   Assessment of no-reflow phenomenon after acute myocardial infarction with harmonic angiography and intravenous pump infusion with Levovist: Comparison with intracoronary contrast injection [J].
Agati, L ;
Funaro, S ;
Bilotta, F .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (08) :773-781
[2]  
Agati L, 1997, EUR HEART J, V18, P771
[3]   Myocardial blood volume and the amount of viable myocardium early after mechanical reperfusion of acute myocardial infarction:: prospective study using venous contrast echocardiography [J].
Andrássy, P ;
Zielinska, M ;
Busch, R ;
Schömig, A ;
Firschke, C .
HEART, 2002, 87 (04) :350-355
[4]   Harmonic power Doppler contrast echocardiography:: Preliminary clinical results [J].
Becher, H ;
Tiemann, K ;
Schlief, R ;
Lüderitz, B ;
Nanda, NC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (06) :637-642
[5]   Myocardial contrast echocardiography versus dobutamine echocardiography for predicting functional recovery after acute myocardial infarction treated with primary coronary angioplasty [J].
Bolognese, L ;
Antoniucci, D ;
Rovai, D ;
Buonamici, P ;
Cerisano, G ;
Santoro, GM ;
Marini, C ;
LAbbate, A ;
Fazzini, PF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (07) :1677-1683
[6]  
Calnon DA, 1997, CIRCULATION, V96, P2353
[7]   Detection of angiographically significant coronary artery disease with accelerated intermittent imaging after intravenous administration of ultrasound contrast material [J].
Cwajg, J ;
Xie, F ;
O'Leary, E ;
Kricsfeld, D ;
Dittrich, H ;
Porter, TR .
AMERICAN HEART JOURNAL, 2000, 139 (04) :675-683
[8]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[9]   Dobutamine-induced hypoperfusion without transient wall motion abnormalities: Less severe ischemia or less severe stress? [J].
Elhendy, A ;
Geleijnse, ML ;
Roelandt, JRTC ;
vanDomburg, RT ;
TenCate, FJ ;
Cornel, JH ;
Reijs, AEM ;
ElSaid, GM ;
Fioretti, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) :323-329
[10]   Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential application in the cardiac catheterization laboratory [J].
Firschke, C ;
Lindner, JR ;
Goodman, NC ;
Skyba, DM ;
Wei, K ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (01) :207-216