Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform

被引:86
作者
Lorsomradee, Suraphong
Lorsomradee, Sratwadee
Cromheecke, Stefanie
De Hert, Stefan G.
机构
[1] Univ Antwerp Hosp, Dept Anesthesiol, B-2650 Edegem, Belgium
[2] Univ Hosp Chiangmai, Dept Anesthesiol, Chiangmai, Thailand
关键词
continuous cardiac output; pulse contour analysis; thermodilution; cardiac surgery; aortic stenosis; aortic insufficiency; intro-aortic balloon pump; phenylephrine; sternotomy;
D O I
10.1053/j.jvca.2007.02.003
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare an arterial pressure-derived cardiac output (APCO) (Vigileo software version 1.07; Edwards Lifesciences, Irvine, CA) and a thermodilution cardiac output (CCO) as methods for measuring cardiac output under different pathologic and experimental conditions that induce changes in arterial waveform morphology. Design: A prospective study. Setting: A university hospital, single institutional. Participants: Fifty-two patients undergoing elective cardiac surgery. Interventions: Simultaneous APCO and CCO were compared in low-risk patients undergoing elective coronary artery surgery (without valvular disease) (control, n = 20), patients with aortic stenosis (AS, n = 10), aortic insufficiency (AI, n = 10), and intra-aortic balloon pump (IABP, n = 12). In the control group, additional data were registered before and after median sternotomy and phenylephrine administration. Measurements and Main Results: In the control group, Bland-Altman showed a bias of -3% (95% limits of agreement: -59% to +53%) before cardiopulmonary bypass (CPB) and of -1% (95% limits of agreement: -51% to +50%) after CPB. In the AS group, the bias was -5% (95% limits of agreement: -34% to +24%) before CPB and 1% (95% limits of agreement: -28 to +30%) after CPB. In the AI group bias was +32% (95% limits of agreement: -4% to +68%) before CPB and -2% (95% limits of agreement: -35% to +32%) after CPB. Median sternotomy decreased CCO by 10% +/- 10%, whereas it increased APCO by 56% +/- 28%. Phenylephrine administration decreased CCO by 11% +/- 16%, whereas it increased APCO by 55% +/- 34%. Conclusions: Cardiac output measurement based on uncalibrated pulse contour analysis is able to reflect cardiac output measured with the continuous thermodilution method in patients undergoing uncomplicated coronary artery surgery. However, in situations in which the arterial pressure waveform is changed, agreement between techniques may be altered and data obtained with uncalibrated pulse contour analysis may become less reliable. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:636 / 643
页数:8
相关论文
共 27 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Length-dependent regulation of left ventricular function in coronary surgery patients [J].
De Hert, SG ;
Gillebert, TC ;
Ten Broecke, PW ;
Moulijn, AC .
ANESTHESIOLOGY, 1999, 91 (02) :379-387
[3]   Monitoring cardiac output using the femoral and radial arterial pressure waveform [J].
de Wilde, R. B. P. ;
Breukers, R. B. G. E. ;
van den Berg, P. C. M. ;
Jansen, J. R. C. .
ANAESTHESIA, 2006, 61 (08) :743-746
[4]   Recovery of systolic and diastolic left ventricular function early after cardiopulmonary bypass [J].
DeHert, SG ;
Rodrigus, IE ;
Haenen, LR ;
DeMulder, PA ;
Gillebert, TC .
ANESTHESIOLOGY, 1996, 85 (05) :1063-1075
[5]  
Felbinger TW, 2005, ANAESTHESIST, V54, P755, DOI 10.1007/s00101-005-0847-9
[6]  
Godje O, 2001, Med Sci Monit, V7, P1344
[7]  
Gödje O, 2002, CRIT CARE MED, V30, P52
[8]  
Headley Jan M, 2006, Crit Care Nurs Clin North Am, V18, P179, DOI 10.1016/j.ccell.2006.01.004
[9]  
HORSWELL J, 2005, ANESTHESIOLOGY, V103, P834
[10]   Analysis of the accuracy of continuous thermodilution cardiac output measurement - Comparison with intermittent thermodilution and Fick cardiac output measurement [J].
Jacquet, L ;
Hanique, G ;
Glorieux, D ;
Matte, P ;
Goenen, M .
INTENSIVE CARE MEDICINE, 1996, 22 (10) :1125-1129