Fractional flow reserve, absolute and relative coronary blood mow velocity reserve in relation to the results of technetium-99m sestamibi single-photon emission computed tomography in patients with two-vessel coronary artery disease

被引:89
作者
Chamuleau, SAJ
Meuwissen, M
van Eck-Smit, BLF
Koch, KT
de Jong, A
de Winter, RJ
Schotborgh, CE
Bax, M
Verberne, HJ
Tijssen, JGP
Piek, JJ
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Cardiol, NL-1100 DD Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1100 DD Amsterdam, Netherlands
关键词
D O I
10.1016/S0735-1097(01)01173-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to perform a direct comparison between perfusion scintigraphic results and intracoronary-derived hemodynamic variables (fractional flow reserve [FFR]; absolute and relative coronary flow velocity reserve [CFVR and rCFVR, respectively]) in patients with two-vessel disease. BACKGROUND There is limited information on the diagnostic accuracy of intracoronary-derived variables (CFVR, FFR and rCFVR) in patients with multivessel disease. METHODS Dipyiramole technetium-99m sestamibi (MIBI) single-photon emission computed tomography (SPECT) was performed in 127 patients. The presence of reversible perfusion defects in the region of interest was determined. Within one week, angiography was performed; CFVR, rCFVR and FFR were determined in 161 coronary lesions after intracoronary administration of adenosine. The predictive value for the presence of reversible perfusion defects on MIBI SPECT of CFVR, rCFVR and FFR was evaluated by the area under the curve (AUC) of the receiver operating characteristics curves. RESULTS The mean percentage diameter stenosis was 57% (range 35% to 85%), as measured by quantitative coronary angiography. Using per-patient analysis, the AUCs for CFVR (0.70 +/- 0.052), rCFVR (0.72 +/- 0.051) and FFR (0.76 +/- 0.050) were not significantly different (p = NS). The percentages of agreement with the results of MIBI SPECT were 76%, 78% and 77% for CFVR, rCFVR and FFR, respectively. Per-lesion analysis, using all 161 measured lesions, yielded similar results. CONCLUSIONS The diagnostic accuracy of three intracoronary-derived hemodynamic variables, as compared with the results of perfusion scintigraphy, is similar in patients with two-vessel coronary artery disease. Cut-off values of 2.0 for CFVR, 0.65 for rCFVR and 0.75 for FFR call be used for clinical decision-making in this patient cohort. Discordant results were obtained ill 23%, of the cases that require prospective evaluation for appropriate patient management. (J Am Coll Cardiol 2001;37:1316-22) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1316 / 1322
页数:7
相关论文
共 27 条
[1]   Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions [J].
Abizaid, AS ;
Mintz, GS ;
Mehran, R ;
Abizaid, A ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Wu, HS ;
Pappas, C ;
Kent, KM ;
Leon, MB .
CIRCULATION, 1999, 100 (03) :256-261
[2]   Comparison of exercise electrocardiography and dobutamine echocardiography with invasively assessed myocardial fractional flow reserve in evaluation of severity of coronary arterial narrowing [J].
Bartunek, J ;
VanSchuerbeeck, E ;
deBruyne, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (04) :478-&
[3]   Improved assessment of coronary stenosis severity using the relative flow velocity reserve [J].
Baumgart, D ;
Haude, M ;
Goerge, G ;
Ge, JB ;
Vetter, S ;
Dagres, N ;
Heusch, G ;
Erbel, R .
CIRCULATION, 1998, 98 (01) :40-46
[4]  
Chamuleau SAJ, 2000, CIRCULATION, V102, P477
[5]   Which variable of stenosis severity best describes the significance of an isolated left anterior descending coronary artery lesion? Correlation between quantitative coronary angiography, intracoronary Doppler measurements and high dose dipyridamole echocardiography [J].
Danzi, GB ;
Pirelli, S ;
Muri, L ;
Testa, R ;
Ciliberto, GR ;
Massa, D ;
Lotto, AA ;
Campolo, L ;
Parodi, O .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :526-533
[6]  
De Bruyne B, 1999, CIRCULATION, V100, P376
[7]   RELATION BETWEEN MYOCARDIAL FRACTIONAL FLOW RESERVE CALCULATED FROM CORONARY PRESSURE MEASUREMENTS AND EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA [J].
DEBRUYNE, B ;
BARTUNEK, J ;
SYS, SU ;
HEYNDRICKX, GR .
CIRCULATION, 1995, 92 (01) :39-46
[8]   DOPPLER GUIDE-WIRE FLOW-VELOCITY INDEXES MEASURED DISTAL TO CORONARY STENOSES ASSOCIATED WITH REVERSIBLE THALLIUM PERFUSION DEFECTS [J].
DEYCHAK, YA ;
SEGAL, J ;
REINER, JS ;
ROHRBECK, SC ;
THOMPSON, MA ;
LUNDERGAN, CF ;
ROSS, AM ;
WASSERMAN, AG .
AMERICAN HEART JOURNAL, 1995, 129 (02) :219-227
[9]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[10]   Safety of deferring angioplasty in patients with normal coronary flow velocity reserve [J].
Ferrari, M ;
Schnell, B ;
Werner, GS ;
Figulla, HR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (01) :82-87