Polymeric heart valves for surgical implantation, catheter-based technologies and heart assist devices

被引:126
作者
Bezuidenhout, Deon [1 ,2 ]
Williams, David F. [2 ,3 ]
Zilla, Peter [1 ,2 ]
机构
[1] Univ Cape Town, Cardiovasc Res Unit, MRC IUCHRU, ZA-7925 Cape Town, South Africa
[2] Strait Access Technol Pty Ltd, Cape Town, South Africa
[3] Wake Forest Inst Regenerat Med, Winston Salem, NC USA
基金
新加坡国家研究基金会; 英国医学研究理事会;
关键词
Heart valve prostheses; Polymeric; Surgical; TAVI; LVAD; TOTAL ARTIFICIAL-HEART; ENDOTHELIAL-CELL ADHESION; AORTIC-VALVE; MITRAL-VALVE; IN-VIVO; SPECIAL DESIGN; BLOOD PUMPS; MULTIBLOCK POLYURETHANES; HYDRODYNAMIC FUNCTION; RESIST CALCIFICATION;
D O I
10.1016/j.biomaterials.2014.09.013
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Efficient function and long-term durability without the need for anticoagulation, coupled with the ability to be accommodated in many different types of patient, are the principal requirements of replacement heart valves. Although the clinical use of valves appeared to have remained steady for several decades, the evolving demands for the elderly and frail patients typically encountered in the developed world, and the needs of much younger and poorer rheumatic heart disease patients in the developing world have now necessitated new paradigms for heart valve technologies and associated materials. This includes further consideration of durable elastomeric materials. The use of polymers to produce flexible leaflet valves that have the benefits of current commercial bioprosthetic and mechanical valves without any of their deficiencies has been held desirable since the mid 1950s. Much attention has been focused on thermoplastic polyurethanes in view of their generally good physico-chemical properties and versatility in processing, coupled with the improving biocompatibility and stability of recent formulations. Accelerated in vitro durability of between 600 and 1000 million cycles has been achieved using polycarbonate urethanes, and good resistance to degradation, calcification and thrombosis in vivo has been shown with some polysiloxane-based polyurethanes. Nevertheless, polymeric valves have remained relegated to use in temporary ventricular assist devices for bridging heart failure patients to transplantation. Some recent studies suggest that there is a greater degree of instability in thermoplastic materials than hitherto believed so that significant challenges remain in the search for the combination of durability and biocompatibility that would allow polymeric valves to become a clinical reality for surgical implantation. Perhaps more importantly, they could become candidates for use in situations where minimally invasive transcatheter procedures are used to replace diseased valves. Being amenable to relatively inexpensive mass production techniques, the attainment of this goal could benefit very large numbers of patients in developing and emerging countries who currently have no access to treatment for rheumatic heart disease that is so prevalent in these areas. This review discusses the evolution and current status of polymeric valves in wide-ranging circumstances. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6 / 25
页数:20
相关论文
共 175 条
[1]
POLYURETHANE ARTIFICIAL HEART VALVES IN ANIMALS [J].
AKUTSU, T ;
DREYER, B ;
KOLFF, WJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1959, 14 (06) :1045-1048
[2]
Bisphosphonate derivatized polyurethanes resist calcification [J].
Alferiev, I ;
Vyavahare, N ;
Song, CX ;
Connolly, J ;
Hinson, JT ;
Lu, ZB ;
Tallapragada, S ;
Bianco, R ;
Levy, R .
BIOMATERIALS, 2001, 22 (19) :2683-2693
[3]
Prevention of polyurethane valve cusp calcification with covalently attached bisphosphonate diethylamino moieties [J].
Alferiev, I ;
Stachelek, SJ ;
Lu, ZB ;
Fu, AL ;
Sellaro, TL ;
Connolly, JM ;
Bianco, RW ;
Sacks, MS ;
Levy, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (02) :385-395
[4]
TRANSLUMINAL IMPLANTATION OF ARTIFICIAL-HEART VALVES - DESCRIPTION OF A NEW EXPANDABLE AORTIC-VALVE AND INITIAL RESULTS WITH IMPLANTATION BY CATHETER TECHNIQUE IN CLOSED CHEST PIGS [J].
ANDERSEN, HR ;
KNUDSEN, LL ;
HASENKAM, JM .
EUROPEAN HEART JOURNAL, 1992, 13 (05) :704-708
[5]
Use of the AB5000™ Ventricular Assist Device in Cardiogenic Shock After Acute Myocardial Infarction [J].
Anderson, Mark ;
Smedira, Nicholas ;
Samuels, Louis ;
Madani, Michael ;
Naka, Yoshifumi ;
Acker, Michael ;
Hout, Mariah ;
Benali, Karim .
ANNALS OF THORACIC SURGERY, 2010, 90 (03) :706-712
[6]
Ten-year experience with handmade trileaflet polytetrafluoroethylene valved conduit used for pulmonary reconstruction [J].
Ando, Makoto ;
Takahashi, Yukihiro .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :124-131
[7]
[Anonymous], 1990, HDB PLASTIC MAT TECH
[8]
[Anonymous], ANN THORAC SURG
[9]
Pediatric bridge to heart transplantation:: Application of the Berlin heart, Medos and Thoratec ventricular assist devices [J].
Arabía, FA ;
Tsau, PH ;
Smith, RG ;
Nolan, PE ;
Paramesh, V ;
Bose, RK ;
Woolley, DS ;
Sethi, GK ;
Rhenman, BE ;
Copeland, JG .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (01) :16-21
[10]
Percutaneous valve replacement: a novel low-profile polyurethane valved stent [J].
Attmann, Tim ;
Steinseifer, Ulrich ;
Cremer, Jochen ;
Lutter, Georg .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (02) :379-379