Thin-layer chromatography mass spectrometry using activated carbon, surface-assisted laser desorption/ionization

被引:94
作者
Chen, YC [1 ]
Shiea, J [1 ]
Sunner, J [1 ]
机构
[1] Montana State Univ, Dept Chem & Biochem, Bozeman, MT 59717 USA
关键词
surface-assisted laser desorption ionization; mass spectrometry; prometryn; hydrochlorothiazide; angiotensin; bradykinin; arginine;
D O I
10.1016/S0021-9673(98)00726-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of compounds separated by thin-layer chromatography (TLC) by surface-assisted laser desorption ionization (SALDI) mass spectrometry has been demonstrated. The compounds are analyzed from the surface of the intact TLC plate, and the preparation of the TLC plate is rapid and robust: the gel surface is covered with 2 mu m activated carbon particles, and glycerol is added. Analytes diffuse from the interior of the gel to the surface where they are adsorbed onto the activated carbon. A nitrogen laser is used to desorb analyte ions from the carbon particles in a time-of-flight mass spectrometer. A wide range of organic compounds, including peptides, can be detected, either as protonated or as cationized molecules. Interference with "matrix peaks" is limited since background TLC-SALDI mass spectra typically show only a few intense peaks at low mass. The detection limit for bradykinin from a developed plate is approximately 25 ng (calculated for S/N=3). The mass resolution (FWHM) varied from a high of about 500 to a low of about 100. This variability was likely due to surface charging. Methods to improve both mass resolution and sensitivity of TLC-SALDI are suggested. (C) 1998 Elsevier Science BN. All rights reserved.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 32 条
  • [1] BUSCH K L, 1992, Journal of Planar Chromatography - Modern TLC, V5, P9
  • [2] PLANAR CHROMATOGRAPHY COUPLED TO MASS-SPECTROMETRY
    BUSCH, KL
    MULLIS, JO
    CARLSON, RE
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (08): : 1695 - 1713
  • [3] BUSCH KL, 1991, HDB THIN LAYER CHROM, P183
  • [4] CHEN YC, 1996, P 44 ASMS C MASS SPE, P642
  • [5] Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry
    Dale, MJ
    Knochenmuss, R
    Zenobi, R
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (19) : 3321 - 3329
  • [6] COMBINED THIN-LAYER CHROMATOGRAPHY-MASS SPECTROMETRY - AN APPLICATION OF CF-252 PLASMA DESORPTION MASS-SPECTROMETRY FOR DRUG-MONITORING
    DANIGEL, H
    SCHMIDT, L
    JUNGCLAS, H
    PFLUGER, KH
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1985, 12 (09): : 542 - 544
  • [7] PHASE-TRANSITION MATRIX FOR CHROMATOGRAPHY SECONDARY ION MASS-SPECTROMETRY
    DIDONATO, GC
    BUSCH, KL
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (14) : 3231 - 3232
  • [8] AUTOMATED SAMPLE TRANSPORT-SYSTEM FOR CHROMATOGRAPHY SECONDARY ION MASS-SPECTROMETRY
    DUFFIN, KL
    FLURER, RA
    BUSCH, KL
    SEXTON, LW
    DORSETT, JL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (06) : 1071 - 1074
  • [9] IMAGING ANALYSIS AND SELECTED SEQUENCE MONITORING OF SMALL PEPTIDES USING PLANAR CHROMATOGRAPHY SECONDARY ION MASS-SPECTROMETRY
    DUNPHY, JC
    BUSCH, KL
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (05): : 405 - 410
  • [10] THIN-LAYER CHROMATOGRAPHY MASS-SPECTROMETRY USING INFRARED-LASER DESORPTION
    FANIBANDA, T
    MILNES, J
    GORMALLY, J
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 140 : 127 - 132