Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection

被引:70
作者
Elke, K [1 ]
Jermann, E [1 ]
Begerow, J [1 ]
Dunemann, L [1 ]
机构
[1] Med Inst Umwelthyg, Dept Analyt Chem, D-40225 Dusseldorf, Germany
关键词
air analysis; environmental analysis; sample handling; headspace solid-phase microextraction; benzene; toluene; ethylbenzene; xylenes; volatile organic compounds;
D O I
10.1016/S0021-9673(98)00736-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An improved analytical method for passive air sampling is presented based on a combination of commercially available diffusive samplers with headspace solid-phase microextraction and high-resolution gas chromatography with flame ionization detection (HRGC-FID). This procedure is targeted for short-term BTEX (benzene, toluene, ethylbenzene and o-, m- and p-xylenes) determinations at environmental concentrations and can be applied for sampling intervals between 30 min and 24 h. The analytes are adsorbed onto the charcoal pad of a passive sampler and then extracted with carbon disulphide-methanol. After removal of the carbon disulphide by xanthation, the BTEXs are enriched on a Carboxen SPME fiber, thermally desorbed and analysed by HRGC-FID. Detection limits for a sampling interval of 2 h are between 0.4 and 2 mu g/m(3), within-series precision ranges between 6.6 and 12.8%, day-to-day precision is between 11.1 and 15.2%. The results obtained with this procedure are validated by comparison with active sampling. Detection limits and a further reduction of the sampling time are limited by blanks of the chemicals and the diffusive samplers. Procedures to eliminate these blanks are described in detail. Applications such as the determination of BTEXs in indoor air inside buildings, inside a train and a car are presented, indicating the usefulness of the described procedure for short-term measurements of environmental BTEX concentrations. An advantage of passive samplers is the storage stability for at least six months, which is essential for its use in large epidemiological studies. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 27 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]   PASSIVE SAMPLING FOR VOLATILE ORGANIC-COMPOUNDS (VOCS) IN AIR AT ENVIRONMENTALLY RELEVANT CONCENTRATION LEVELS [J].
BEGEROW, J ;
JERMANN, E ;
KELES, T ;
RANFT, U ;
DUNEMANN, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (06) :549-554
[4]   Screening method for the determination of 28 volatile organic compounds in indoor and outdoor air at environmental concentrations using dual-column capillary gas chromatography with tandem electron-capture-flame ionization detection [J].
Begerow, J ;
Jermann, E ;
Keles, T ;
Koch, T ;
Dunemann, L .
JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) :181-191
[5]  
BOGEMANN M, 1955, HOUBEN WEYL METHODEN, V9, P810
[6]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[7]   THE VALIDATION OF A PASSIVE SAMPLER FOR INDOOR AND OUTDOOR CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS [J].
COHEN, MA ;
RYAN, PB ;
YANAGISAWA, Y ;
HAMMOND, SK .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (07) :993-997
[8]  
EDELMANN G, 1983, ULLMANNS ENCY TECHNI, P511
[9]  
Fromme H, 1998, ZBL HYG UMWELTMED, V200, P505
[10]  
Holcomb L.C., 1995, INDOOR ENVIRON, V4, P7, DOI DOI 10.1177/1420326X9500400103