摘要
While the demand for reduction in CO2 emission is increasing, the cost of the CO2 capture processes remains a limiting factor for large-scale application. Reducing the cost of the capture system by improving the process and the solvent used must have a priority in order to apply this technology in the future. In this paper, a definition of the economic baseline for post-combustion CO2 capture from 600 MWe bituminous coal-fired power plant is described. The baseline capture process is based on 30% (by weight) aqueous solution of monoethanolamine (MEA). A process model has been developed previously using the Aspen Plus simulation programme where the baseline CO2-removal has been chosen to be 90%. The results from the process modelling have provided the required input data to the economic modelling. Depending on the baseline technical and economical results, an economical parameter study for a CO2 capture process based on absorption/desorption with MEA solutions was performed. Major capture cost reductions can be realized by optimizing the lean solvent loading, the amine solvent concentration, as well as the stripper operating pressure. A minimum CO2 avoided cost of (sic) 33 tonne(-1) CO2 was found for a lean solvent loading of 0.3 mol CO2/Mol MEA, using a 40 wt.% MEA solution and a stripper operating pressure of 210 kPa. At these conditions 3.0 GJ/tonne CO2 of thermal energy was used for the solvent regeneration. This translates to a (sic) 22 MWh(-1) increase in the cost of electricity, compared to (sic) 31.4 MWh(-1) for the power plant without capture. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 13 条
[1]  
ABUZAHRA M, 2006, INT J GREE IN PRESS
[2]  
[Anonymous], CARB DIOX CAPT STOR
[3]   THE KERR-MCGEE ABB LUMMUS CREST TECHNOLOGY FOR THE RECOVERY OF CO2 FROM STACK GASES [J].
BARCHAS, R ;
DAVIS, R .
ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (5-8) :333-340
[4]  
CHAPEL D, 1999, CAN SOC CHEM ENG
[5]  
Hendriks C., 2003, EC CASE CARBON DIOXI
[6]  
*IEA GREENH GAS R, 2004, PH433 IEA GREENH GAS
[7]  
Mariz CL, 1998, J CAN PETROL TECHNOL, V37, P42
[8]  
PERRY M, 1997, PERRYS CHEM ENG HDB
[9]  
Peters M.S., 2003, Plant Design and Economics for Chemical Engineers, V5th
[10]  
Rao A. B., 2002, TECHNICAL EC ENV ASS