Detection of picomolar levels of interleukin-8 in human saliva by SPR

被引:125
作者
Yang, CY
Brooks, E
Li, Y
Denny, P
Ho, CM
Qi, FX
Shi, WY
Wolinsky, L
Wu, B
Wong, DTW
Montemagno, CD
机构
[1] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Inst Dent Res, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Sch Engn & Appl Sci, Dept Mech & Aerosp Engn, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Div Head & Neck Surg, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, Inst Mol Biol, Los Angeles, CA 90095 USA
关键词
D O I
10.1039/b504737d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Researchers at UCLA have discovered that the levels of interleukin-8 (IL-8) protein in the saliva of healthy individuals and patients with oropharyngeal squamous cell carcinoma (OSCC) are 30 pM and 86 pM, respectively. In this study, we present the development of the first immunoassay for the quantification of picomolar IL-8 concentrations in human saliva using Biacore surface plasmon resonance (SPR) in a microfluidic channel. A sandwich assay using two monoclonal antibodies, which recognize different epitopes on the antigen (IL-8), was used. Only 13 minutes were required to determine the quantity of pure IL-8 added to just 100 mu L of either buffer or saliva-based samples. The limit of detection (LOD) of this immunoassay in buffer was 2.5 pM, and the precision of the response for each concentration was <3% of the coefficient of variation. When first analyzing the saliva supernatants, non-specific binding to the surface was observed. By adding carboxymethyl dextran sodium salt ( 10 mg mL(-1)) to compete with the surface dextran and primary antibody for non-specific interactions, the signal to noise ratio was greatly improved. The LOD of this immunoassay in saliva was 184 pM. A minimum concentration of 250 pM of exogenous IL-8 could then be consistently detected in a salivary environment. The precision of the response for each IL-8 concentration tested was,7% of the coefficient of variation. Diagnostic sensitivity for oral cancer can be achieved by pre-concentrating the saliva samples 10 fold prior to SPR analysis, making the target levels of IL-8 300 pM for healthy individuals and 860 pM for oral cancer patients.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 17 条
[1]  
DESHPAPNDE SS, 1996, ENZYME IMMUNOASSAYS, P315
[2]   Detection of streptomycin and dihydrostreptomycin residues in milk, honey and meat samples using an optical biosensor [J].
Ferguson, JP ;
Baxter, GA ;
McEvoy, JDG ;
Stead, S ;
Rawlings, E ;
Sharman, M .
ANALYST, 2002, 127 (07) :951-956
[3]   Development and validation of a biosensor-based immunoassay for progesterone in bovine milk [J].
Gillis, EH ;
Gosling, JP ;
Sreenan, JM ;
Kane, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 267 (02) :131-138
[4]   Human saliva as a diagnostic specimen [J].
Hofman, LF .
JOURNAL OF NUTRITION, 2001, 131 (05) :1621S-1625S
[5]   A review of saliva: Normal composition, flow, and function [J].
Humphrey, SP ;
Williamson, RT .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (02) :162-169
[6]   Direct optical blosensor analysis of folate-binding protein in milk [J].
Indyk, HE ;
Filonzi, EL .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (11) :3253-3258
[7]  
Indyk HE, 2002, J AOAC INT, V85, P72
[8]   IMMOBILIZATION OF PROTEINS TO A CARBOXYMETHYLDEXTRAN-MODIFIED GOLD SURFACE FOR BIOSPECIFIC INTERACTION ANALYSIS IN SURFACE-PLASMON RESONANCE SENSORS [J].
JOHNSSON, B ;
LOFAS, S ;
LINDQUIST, G .
ANALYTICAL BIOCHEMISTRY, 1991, 198 (02) :268-277
[9]  
JONSSON U, 1991, BIOTECHNIQUES, V11, P620
[10]  
Lawrence Herenia P, 2002, J Can Dent Assoc, V68, P170