Assessment of environmental tobacco smoke and respirable suspended particle exposures for nonsmokers in Basel by personal monitoring

被引:16
作者
Phillips, K [1 ]
Howard, DA
Bentley, MC
Alván, G
机构
[1] Covance Labs Ltd, Dept Air Qual Monitoring, Harrogate HG3 1PY, N Yorkshire, England
[2] Huddinge Univ Hosp, Div Clin Pharmacol, Dept Med Lab Sci & Technol, Karolinska Inst, S-14186 Huddinge, Sweden
关键词
nicotine; cotinine; solanesol; housewives; workplace;
D O I
10.1016/S1352-2310(98)00205-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One hundred and ninety-six randomly selected nonsmoking subjects collected air samples close to their breathing zone by wearing personal monitors for 24 h. The study was centred in Basel, Switzerland, and comprised housewives in one group, primarily for assessing exposures in the home, and office workers in a second group to assess the contribution of the workplace to overall exposure. Samples collected were analysed for respirable suspended particles (RSP), nicotine, 3-ethenylpyridine and environmental tobacco smoke (ETS) particles by using ultraviolet absorbance, fluorescence and solanesol measurements. Saliva cotinine analyses were also undertaken to confirm the nonsmoking status of the subjects. Based upon median 24 h time weighted average concentrations, office workers who live and work with smokers were exposed to 39 mu g m(-3) RSP, 6.6 mu g m(-3) ETS particles and 0.90 mu g m(-3) nicotine. Housewives living with smokers were exposed to median concentrations of 34 mu g m(-3) RSP, 1.4 mu g m(-3) ETS particles and 0.60 mu g m(-3) nicotine. Workplaces where smoking occurred were estimated, on average, to contribute between 34 and 46% to annual exposure of ETS particles and nicotine. Based upon 90th percentile values the most highly exposed housewives, those living with smokers, would potentially inhale 18 cigarette equivalents per year whilst the most highly exposed office workers, both living and working with smokers, might inhale 61 cigarette equivalents. The rate at which subjects misreported their nonsmoking status varied between 9.7 and 12.2%. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1889 / 1904
页数:16
相关论文
共 25 条
[1]   Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships [J].
Baek, SO ;
Kim, YS ;
Perry, R .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) :529-544
[2]   DEFICIENT C-OXIDATION OF NICOTINE [J].
BENOWITZ, NL ;
JACOB, P ;
SACHS, DPL .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1995, 57 (05) :590-594
[3]   POOR METABOLIZERS OF NICOTINE AND CYP2D6 POLYMORPHISM [J].
CHOLERTON, S ;
ARPANAHI, A ;
MCCRACKEN, N ;
BOUSTEAD, C ;
TABER, H ;
JOHNSTONE, E ;
LEATHART, J ;
DALY, AK ;
IDLE, JR .
LANCET, 1994, 343 (8888) :62-63
[4]   A REVIEW OF THE USE OF SALIVA COTININE AS A MARKER OF TOBACCO-SMOKE EXPOSURE [J].
ETZEL, RA .
PREVENTIVE MEDICINE, 1990, 19 (02) :190-197
[5]   Determination of volatile organic compounds and respirable suspended particulate matter in New Jersey and Pennsylvania homes and workplaces [J].
Heavner, DL ;
Morgan, WT ;
Ogden, MW .
ENVIRONMENT INTERNATIONAL, 1996, 22 (02) :159-183
[6]   INDOOR AIR-QUALITY AND ENVIRONMENTAL TOBACCO-SMOKE - CONCENTRATION AND EXPOSURE [J].
HOLCOMB, LC .
ENVIRONMENT INTERNATIONAL, 1993, 19 (01) :9-40
[7]  
Jenkins RA, 1996, J EXPO ANAL ENV EPID, V6, P473
[9]  
MCNEILL AD, 1987, BRIT J ADDICT, V82, P1355
[10]   PARTICULATE MATTER LESS-THAN-10 MU-M (PM(10)) AND TOTAL SUSPENDED PARTICULATES (TSP) IN URBAN, RURAL AND ALPINE AIR IN SWITZERLAND [J].
MONN, C ;
BRAENDLI, O ;
SCHAEPPI, G ;
SCHINDLER, C ;
ACKERMANNLIEBRICH, U ;
LEUENBERGER, P ;
TEAM, S .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (19) :2565-2573