Experimental flash points of industrial amines

被引:5
作者
Mitchell, JW [1 ]
Vratsanos, MS [1 ]
Hanley, BF [1 ]
Parekh, VS [1 ]
机构
[1] Air Prod & Chem Inc, Allentown, PA 18195 USA
关键词
D O I
10.1021/je980144h
中图分类号
O414.1 [热力学];
学科分类号
摘要
Closed cup flash points have been measured at atmospheric pressure for 37 industrially important amines and amine solutions. The flash point measurements were made using either an ERDCO Engineering Corp. closed cup flash point tester or a Grabner Instruments automated closed cup flash point tester. The measured flash points have been compared against the standard literature sources for such material safety data, when available. The measured flash points show good agreement with reported values for 9 out of the 37 systems reported here. While literature data are found lacking for 19 amines, large discrepancies have been noted in reported values for the remaining 9 materials.
引用
收藏
页码:209 / 211
页数:3
相关论文
共 9 条
[1]  
FAWCETT HH, 1982, SAFETY ACCIDENT PREV, P342
[2]   A model for the calculation and the verification of closed cup flash points for multicomponent mixtures [J].
Hanley, B .
PROCESS SAFETY PROGRESS, 1998, 17 (02) :86-97
[3]  
HU J, 1970, HYDROCARB PROCESS, V49, P213
[4]  
Lenga R. E., 1988, SIGMA ALDRICH LIB CH
[5]  
Lewis R. J, 1996, SAXS DANGEROUS PROPE
[6]  
National Fire Protection Association, 1994, FIR PROT GUID HAZ MA
[7]  
PRUGH RW, 1970, J CHEM EDUC, V50, pA85
[8]  
Sax Irving, 1979, DANGEROUS PROPERTIES
[9]  
WALSHAM JG, 1978, ADV CHEM SERIES, V124