Efficacy of pulmonary vein isolation by cryoballon ablation in patients with paroxysmal atrial fibrillation

被引:98
作者
Klein, Gunnar [1 ]
Oswald, Hanno [1 ]
Gardiwal, Ajmal [1 ]
Luesebrink, Ulrich [1 ]
Lissel, Christoph [1 ]
Yu, Hong [1 ]
Drexler, Helmut [1 ]
机构
[1] Hannover Med Sch, Dept Cardiovasc Med, D-30625 Hannover, Germany
关键词
ablation; atrial fibrillation; cryoablation; cryoballoon;
D O I
10.1016/j.hrthm.2008.02.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Radiofrequency ablation of pulmonary veins (PVs) has emerged as an effective treatment for patients with paroxysmal atrial fibrillation (AF). However, serious complications raise concern about an even wider application. In terms of safety, cryoenergy has advantages compared with radiofrequency. A new cryoenergy balloon catheter has been recently developed to make AF ablation shorter and safer. OBJECTIVE The purpose of this study was to test the 6-month efficacy of this new device for ablation of paroxysmal AF. METHODS Twenty-one patients with highly symptomatic paroxysmal AF, normal left atrial size, and frequent episodes of AF were included. All PVs were targeted during cryoballoon ablation. Patients received 24-hour Hotter electrocardiograms (ECGs) and event recorder during follow-up after 1, 3, and 6 months. RESULTS A total of 81 (95%) of 85 PVs could be completely isolated with a single-balloon technique. Procedure time was 165 +/- 35 minutes, and fluoroscopy time was 39 +/- 9 minutes. After 6 months, 86% of the patients were free of symptomatic AF. In two of three patients with recurrence of AF, complete PV isolation has not been achieved initially. After a second procedure (1.04 procedures per patient), 90% of the patients were free of symptomatic AF. Three phrenic nerve palsies occurred during ablation of the right superior PV; two completely resolved after 6 and 9 months, and one is still persisting after 2 months. CONCLUSION This is the first study that reports the results of the new cryoballoon AF ablation approach showing 86% freedom from AF recurrence after 6 months. Cryoballoon PV ablation promises to be effective for patients with paroxysmal AF and normally sized left atria.
引用
收藏
页码:802 / 806
页数:5
相关论文
共 17 条
[1]   Ablation of atrial fibrillation in humans using a balloon-based ablation system: Identification of the site of phrenic nerve damage using pacing maneuvers and CARTO [J].
Antz, Matthias ;
Chun, Kr Julian ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (11) :1242-1245
[2]   Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation [J].
Cappato, R ;
Calkins, H ;
Chen, SA ;
Davies, W ;
Iesaka, Y ;
Kalman, J ;
Kim, YH ;
Klein, G ;
Packer, D ;
Skanes, A .
CIRCULATION, 2005, 111 (09) :1100-1105
[3]   Transvenous catheter ice mapping and cryoablation of the atrioventricular node in dogs [J].
Dubuc, M ;
Roy, D ;
Thibault, B ;
Ducharme, A ;
Tardif, JC ;
Villemaire, C ;
Leung, TK ;
Talajic, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (10) :1488-1498
[4]   ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation - Executive summary [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curbs, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Anderson, Jeffery L. ;
Antman, Elliott M. ;
Halperin, Jonathan L. ;
Hunt, Sharon Ann ;
Nishimura, Rick ;
Ornato, Joseph P. ;
Page, Richard L. ;
Riegel, Barbara ;
Priori, Silvia G. ;
Blanc, Jean-Jacques ;
Budaj, Andrzej ;
Camm, A. John ;
Dean, Veronica ;
Deckers, Jaap W. ;
Despres, Catherine ;
Dickstein, Kenneth ;
Lekakis, John ;
McGregor, Keith ;
Metra, Marco ;
Morais, Joao ;
Osterspey, Ady ;
Tamargo, Juan Luis ;
Zamorano, Jose Luis .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (04) :854-906
[5]   Cryothermic ablation within the coronary sinus of an epicardial posterolateral pathway [J].
Gaita, F ;
Paperini, L ;
Riccardi, R ;
Ferraro, A .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (11) :1160-1163
[6]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[7]   Pulmonary vain stenosis and remodeling after electrical isolation for treatment of atrial fibrillation: Short- and medium-term follow-up [J].
Jin, YZ ;
Ross, DL ;
Thomas, SP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10) :1362-1370
[8]   Cryoablation inside the pulmonary vein after failure of radiofrequency antral isolation [J].
Kenigsberg, David N. ;
Wood, Mark A. ;
Alaeddini, Jamshid ;
Ellenbogen, Kenneth A. .
HEART RHYTHM, 2007, 4 (08) :992-996
[9]   Lower incidence of thrombus formation with cryoenergy versus radiofrequency catheter ablation [J].
Khairy, P ;
Chauvet, P ;
Lehmann, J ;
Lambert, J ;
Macle, L ;
Tanguay, JF ;
Sirois, MG ;
Santoianni, D ;
Dubuc, M .
CIRCULATION, 2003, 107 (15) :2045-2050
[10]   First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation [J].
Natale, A ;
Pisano, E ;
Shewchik, J ;
Bash, D ;
Fanelli, R ;
Potenza, D ;
Santarelli, P ;
Schweikert, R ;
White, R ;
Saliba, W ;
Kanagaratnam, L ;
Tchou, P ;
Lesh, M .
CIRCULATION, 2000, 102 (16) :1879-1882