Accuracy of detecting screw penetration of the acetabulum with intraoperative fluoroscopy and computed tomography

被引:40
作者
Carmack, DB
Moed, BR
McCarroll, K
Freccero, D
机构
[1] Detroit Receiving Hosp, Dept Radiol, Detroit, MI 48201 USA
[2] Wayne State Univ, Sch Med, Detroit, MI 48201 USA
[3] Wayne State Univ, Ctr Hlth, Dept Orthopaed Surg, Detroit, MI 48201 USA
关键词
D O I
10.2106/00004623-200109000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this study was to determine the accuracy of computed tomography and fluoroscopy in assessing joint penetration by periacetabular screws. Methods: A 3.5-mm acetabular periarticular screw was inserted in each of thirty-nine cadaveric hemipelves. Twenty screws were intentionally directed to violate the articular surface, whereas nineteen screws were positioned to avoid the articular surface. Using two fluoroscopic views (tangential and axial) in a manner simulating the clinical setting, an examiner blinded to the actual screw location determined whether each screw was violating the articular surface. In addition, each hemipelvis was examined with computed tomography with use of two different techniques: (1) a 1-mm slice thickness at 1-mm intervals, and (2) a 4-mm slice thickness at 3-mm intervals. Each scan was evaluated by another examiner who was blinded to the actual screw location. Sensitivity, specificity, and percent correct interpretations were then calculated for each method. Results: The sensitivity, specificity, and percent correct interpretations were 95%, 84%, and 90%, respectively, for axial fluoroscopy; 85%, 89%, and 87% for tangential fluoroscopy; 100%, 84%, and 92% for the computed tomography scans with a 1-mm slice thickness at 1-mm intervals; and 100%, 58%, and 79% for the computed tomography scans with a 4-mm slice thickness at 3-mm intervals. Tangential fluoroscopy was found to be more specific than the computed tomography scans with a 4-mm slice thickness at 3-mm intervals (p = 0.02). No other significant differences were found. Conclusions: Fluoroscopy and computed tomography are equally accurate for determining intra-articular screw penetration. Computed tomography scans with thick slices (4 mm at 3-mm intervals) have a low specificity. Their use postoperatively may lead to a false-positive interpretation of the scan and unnecessary exploration of a hip for screw penetration. Clinical Relevance: Both intraoperative fluoroscopy and postoperative computed tomography are accurate methods for evaluating intra-articular screw penetration. If postoperative computed tomography is used, 1-mm slices at 1-mm intervals should be chosen. Fluoroscopy has the advantage of enabling intraoperative diagnosis.
引用
收藏
页码:1370 / 1375
页数:6
相关论文
共 12 条
[1]
ANDERSON DJ, 1989, COMPUTED BODY TOMOGR, P31
[2]
THE RELIABILITY OF DETECTING SCREW PENETRATION OF THE ACETABULUM BY INTRAOPERATIVE AUSCULTATION [J].
ANGLEN, JO ;
DIPASQUALE, T .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (05) :404-408
[3]
DIRSCHL DR, 2000, ORTHOPAEDIC KNOWLEDG, P305
[4]
Ebraheim N A, 1989, J Orthop Trauma, V3, P196, DOI 10.1097/00005131-198909000-00003
[5]
Helfet DL, 1998, MASTER TECHNIQUES OR, P675
[6]
Kellam JP, 1995, FRACTURES PELVIS ACE, P355
[7]
Letournel E, 1993, FRACTURES ACETABULUM, P417
[8]
MEARS D., 1998, MASTER TECHNIQUES OR, P697
[9]
Moed BR, 1998, MASTER TECHNIQUES OR, P631
[10]
Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery [J].
Norris, BL ;
Hahn, DH ;
Bosse, MJ ;
Kellam, JF ;
Sims, SH .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (06) :414-417