Replacing antibodies with aptamers in lateral flow immunoassay

被引:439
作者
Chen, Ailiang [1 ,2 ]
Yang, Shuming [1 ,2 ]
机构
[1] Chinese Acad Agr Sci, Key Lab Agroprod Qual & Safety, Inst Qual Stand & Testing Technol Agroprod, Beijing 100081, Peoples R China
[2] Minist Agr, Key Lab Agrifood Qual & Safety, Beijing 100081, Peoples R China
基金
对外科技合作项目(国际科技项目);
关键词
Aptamer; Antibody; Lateral flow; Immunochromatography; Strip test; TRIGGERED QUADRATIC AMPLIFICATION; FUNCTIONALIZED GOLD NANOPARTICLES; IN-VITRO SELECTION; LABEL-FREE; COLORIMETRIC DETECTION; DNA APTAMERS; IMMUNOCHROMATOGRAPHIC ASSAY; ELECTROCHEMICAL DETECTION; SYSTEMATIC EVOLUTION; VISUAL DETECTION;
D O I
10.1016/j.bios.2015.04.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Aptamers have been identified against various targets as a type of chemical or nucleic acid ligand by systematic evolution of ligands by exponential enrichment (SELEX) with high sensitivity and specificity. Aptamers show remarkable advantages over antibodies due to the nucleic acid nature and target-induced.structure-switching properties and are widely used to design various fluorescent, electrochemical, or colorimetric biosensors. However, the practical applications of aptamer-based sensing and diagnostics are still lagging behind those of antibody-based tests. Lateral flow imthunoassay (LFIA) represents a well established and appropriate technology among rapid assays because of its low cost and user-friendliness. The antibody-based platform is utilized to detect numerous targets, but it is always hampered by the antibody preparation time, antibody stability, and effect of modification on the antibody. Seeking alternatives to antibodies is an area of active research and is of tremendous importance. Aptamers are receiving increasing attention in lateral flow applications because of a number of important potential performance advantages. We speculate that aptamer-based LFIA may be one of the first platforms for commercial use of aptamer-based diagnosis. This review first gives an introduction to aptamer including the selection process SELEX with its focus on aptamer advantages over antibodies, and then depicts LFIA with its focus on aptamer opportunities in LFIA over antibodies. Furthermore, we summarize the recent advances in the development of aptamer-based lateral flow biosensing assays with the aim to provide a general guide for the design of aptamer-based lateral flow biosensing assays. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:230 / 242
页数:13
相关论文
共 133 条
[1]
Label-free detection of kanamycin using aptamer-based cantilever array sensor [J].
Bai, Xiaojing ;
Hou, Hui ;
Zhang, Bailin ;
Tang, Jilin .
BIOSENSORS & BIOELECTRONICS, 2014, 56 :112-116
[2]
A turn-on fluorescent aptasensor for adenosine detection based on split aptamers and graphene oxide [J].
Bai, Yunfeng ;
Feng, Feng ;
Zhao, Lu ;
Chen, Zezhong ;
Wang, Haiyan ;
Duan, Yali .
ANALYST, 2014, 139 (08) :1843-1846
[3]
Aptamer/thrombin/aptamer-AuNPs sandwich enhanced surface plasmon resonance sensor for the detection of subnanomolar thrombin [J].
Bai, Yunfeng ;
Feng, Feng ;
Zhao, Lu ;
Wang, Chunyu ;
Wang, Haiyan ;
Tian, Maozhong ;
Qin, Jun ;
Duan, Yali ;
He, Xiaoxiao .
BIOSENSORS & BIOELECTRONICS, 2013, 47 :265-270
[4]
Development of a new fluorescence immunochromatography strip for detection of chloramphenicol residues in chicken muscles [J].
Bai, Zhihong ;
Luo, Yunbo ;
Xu, Wentao ;
Gao, Huafang ;
Han, Pei ;
Liu, Tao ;
Wang, Hui ;
Chen, Ailiang ;
Huang, Kunlun .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2013, 93 (15) :3743-3747
[5]
Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[6]
Efficient Selection of Biomineralizing DNA Aptamers Using Deep Sequencing and Population Clustering [J].
Bawazer, Lukmaan A. ;
Newman, Aaron M. ;
Gu, Qian ;
Ibish, Abdullah ;
Arcila, Mary ;
Cooper, James B. ;
Meldrum, Fiona C. ;
Morse, Daniel E. .
ACS NANO, 2014, 8 (01) :387-395
[7]
Non-SELEX selection of aptamers [J].
Berezovski, M ;
Musheev, M ;
Drabovich, A ;
Krylov, SN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (05) :1410-1411
[8]
Quantum dot-based lateral flow immunoassay for detection of chloramphenicol in milk [J].
Berlina, Anna N. ;
Taranova, Nadezhda A. ;
Zherdev, Anatoly V. ;
Vengerov, Yuri Y. ;
Dzantiev, Boris B. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) :4997-5000
[9]
Aptamers as tools for target validation [J].
Blank, M ;
Blind, M .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2005, 9 (04) :336-342
[10]
Nucleic Acid Lateral Flow Immunoassay for the Detection of Pathogenic Bacteria from Food [J].
Blazkova, M. ;
Koets, M. ;
Wichers, J. H. ;
Vanamerongen, A. ;
Fukal, L. ;
Rauch, P. .
CZECH JOURNAL OF FOOD SCIENCES, 2009, 27 :S350-S353