Response relationship of VAS and Likert scales in osteoarthritis efficacy measurement

被引:100
作者
Bolognese, JA
Schnitzer, TJ
Ehrich, EW
机构
[1] Merck Res Labs, Rahway, NJ 07065 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL USA
[3] Alkermes Inc, Med Affairs, Cambridge, MA 02139 USA
关键词
osteoarthritis; visual analog scale; Likert rating scale; endpoint correlation; endpoint precision; endpoint relationship;
D O I
10.1016/S1063-4584(03)00082-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective/Background: Efficacy in osteoarthritis (OA) is principally measured using subjective visual analogue (VAS) and/or Likert scale responses. The relationship between these two scales and their relative precision in discriminating active from placebo treatment in OA patients was determined. Design/Methods: Patient overall pain assessment, and patient and investigator global assessments were each measured on a 100 mm VAS and on a 0 to 4 point Likert scale in a 6-week OA study of rofecoxib vs placebo. The relationship between the VAS and Likert responses was examined graphically and via summary statistics. Analysis of variance was used to assess consistency of the VAS/Likert relationship over time and across the different endpoints. Precision was compared using effect size, and normality of VAS scale of measurement was assessed using the Shapiro-Wilk test. Results: Mean VAS scores and changes from baseline at individual time points were generally highly correlated with corresponding Likert responses (r-values generally approximately 0.7-0.8). The magnitude of VAS values and changes varied depending on endpoint, on the associated magnitude of increment of Likert score, and on the Likert baseline value (i.e., where on the Likert scale the change was occurring). Precision of VAS and Likert responses to detect difference between treatments was generally similar with effect sizes approximately 1. Normality and homogeneity of variance of VAS scores was most closely approximated by actual changes in comparison to percent change or log-transformed measures. Conclusions: VAS and Likert responses are highly correlated and yield similar precision for discriminating treatments in OA patients. Since Likert responses are easier to administer and interpret, they may be preferable to measure OA response. (C) 2003 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 10 条
[1]
Comparative study of self-rating pain scales in rheumatoid arthritis patients [J].
Bellamy, N ;
Campbell, J ;
Syrotuik, J .
CURRENT MEDICAL RESEARCH AND OPINION, 1999, 15 (02) :121-127
[2]
Comparative study of self-rating pain scales in osteoarthritis patients [J].
Bellamy, N ;
Campbell, J ;
Syrotuik, J .
CURRENT MEDICAL RESEARCH AND OPINION, 1999, 15 (02) :113-119
[3]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[4]
Bellamy N., 1988, J ORTHOP RHEUMATOL, V1, P95
[5]
STUDIES WITH PAIN RATING-SCALES [J].
DOWNIE, WW ;
LEATHAM, PA ;
RHIND, VM ;
WRIGHT, V ;
BRANCO, JA ;
ANDERSON, JA .
ANNALS OF THE RHEUMATIC DISEASES, 1978, 37 (04) :378-381
[6]
Ehrich EW, 1999, J RHEUMATOL, V26, P2438
[7]
A COMPARISON OF LIKERT AND VISUAL ANALOG SCALES FOR MEASURING CHANGE IN FUNCTION [J].
GUYATT, GH ;
TOWNSEND, M ;
BERMAN, LB ;
KELLER, JL .
JOURNAL OF CHRONIC DISEASES, 1987, 40 (12) :1129-1133
[8]
THE MEASUREMENT OF CLINICAL PAIN INTENSITY - A COMPARISON OF 6 METHODS [J].
JENSEN, MP ;
KAROLY, P ;
BRAVER, S .
PAIN, 1986, 27 (01) :117-126
[9]
SPILKER B, 1990, QUALITY LIFE ASSESSM, P53
[10]
STREINER DL, 1995, HLTH MEASUREMENT SCA, P33