Control method for integrity of continuous beds

被引:18
作者
Hahn, R [1 ]
Jungbauer, A [1 ]
机构
[1] Univ Agr Sci, Inst Appl Microbiol, A-1190 Vienna, Austria
关键词
continuous beds; monolithic columns; breakthrough curves; stationary phases; LC; proteins; lysozyme;
D O I
10.1016/S0021-9673(00)00938-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monoliths are considered to be the latest version of stationary phases for protein chromatography. They are now becoming popular since they exhibit reduced peak broadening due to low mass transfer resistances. A weak point of monoliths may be an inhomogeneous bed, especially when charged groups are present during co-polymerization. This becomes apparent when a protein solution is loaded onto such a monolith. A biphasic breakthrough curve differing from the sigmoidal-shaped one, is observed. Two error functions were used to approximate the breakthrough curve. From these parameters an estimate of the fraction of flow passing through the homogeneously packed part of the bed as well as the inhomogeneously one was derived. This flow pattern was also confirmed by perfusing ferritin through an inhomogeneous monolith and comparing it to an intact one. Electron microscopy and mercury porosimetry did not indicate any abnormalities in the bed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 25 条
[1]  
CABERA K, 1998, TRENDS ANAL CHEM, V1, P50
[2]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[3]   Silica xerogel as a continuous column support for high-performance liquid chromatography [J].
Fields, SM .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2709-2712
[4]   High-performance membrane chromatography of supercoiled plasmid DNA [J].
Giovannini, R ;
Freitag, R ;
Tennikova, TB .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3348-3354
[5]  
HAHN R, 2000, IN PRESS ANAL CHEM
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS [J].
HJERTEN, S ;
LIAO, JL ;
ZHANG, R .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01) :273-275
[7]  
Iberer G, 1999, LC GC N AM, V17, P998
[8]  
Ishizuka N, 1998, HRC-J HIGH RES CHROM, V21, P477
[9]   APPLICATION OF HIGH-PERFORMANCE MEMBRANE CHROMATOGRAPHY FOR SEPARATION OF ANNEXINS FROM THE PLASMA-MEMBRANES OF LIVER AND ISOLATION OF MONOSPECIFIC POLYCLONAL ANTIBODIES [J].
JOSIC, D ;
LIM, YP ;
STRANCAR, A ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 662 (02) :217-226
[10]   HIGH-PERFORMANCE MEMBRANE CHROMATOGRAPHY OF SERUM AND PLASMA-MEMBRANE PROTEINS [J].
JOSIC, D ;
REUSCH, J ;
LOSTER, K ;
BAUM, O ;
REUTTER, W .
JOURNAL OF CHROMATOGRAPHY, 1992, 590 (01) :59-76