Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects: Outcomes following Transcatheter Closure

被引:60
作者
Johri, Amer M. [1 ]
Witzke, Christian [1 ]
Solis, Jorge [1 ]
Palacios, Igor F. [1 ]
Inglessis, Ignacio [1 ]
Picard, Michael H. [1 ]
Passeri, Jonathan J. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA 02114 USA
关键词
Three-dimensional transesophageal echocardiography; Atrial septal defect; FEASIBILITY; GUIDANCE; DEVICE; FOSSA;
D O I
10.1016/j.echo.2010.12.011
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: Successful transcatheter closure of atrial septal defects (ASDs) requires the accurate assessment of defect size and morphology. Assessment of ASD anatomy may be difficult by two-dimensional (2D) echocardiography. The aim of this study was to test the hypothesis that real-time three-dimensional (3D) transesophageal echocardiography (TEE) may provide more accurate morphologic assessment of ASDs than multiplane 2D TEE. Methods: Twenty-four patients with ASDs were imaged using 2D and real-time 3D TEE. ASD shape and size were assessed using 3D TEE retrospectively. Maximal ASD dimensions obtained by 3D TEE were compared with unstretched and balloon-stretched dimensions on 2D TEE. Planimetered defect area by 3D TEE was compared with area calculated using the ellipse formula from 2D imaging. Twenty of the 24 patients underwent transcatheter ASD closure. Closure device size was based on findings on 2D TEE. Follow-up was conducted by 2D transthoracic echocardiography. Results: Of the 24 ASDs, 6 (25%) were circular, 10 (42%) were oval, and 8 (33%) were complex in shape. The mean maximal dimension was larger by 3D TEE compared with 2D TEE (1.8 +/- 0.8 vs 1.5 +/- 0.6 cm; P < .05). There was no difference in the mean area measured by either modality, but for complex-shaped defects, area measured by 3D TEE was larger than that by 2D TEE (2.8 +/- 1.3 vs 1.7 +/- 1.4 cm(2); P < .05). Follow-up transthoracic echocardiography was available for 19 of the 20 patients undergoing transcatheter closure. Nine patients had residual right-to-left shunting 1 to 6 months after ASD closure, and the majority of these were complex in shape. In patients with residual shunting, ASD area by 3D TEE was 27% larger than by 2D TEE, whereas in patients without residual shunting, there was significantly less discrepancy between 3D and 2D areas (19%; P = .0027). Conclusions: Three-dimensional TEE can identify ASD shape. Maximal dimensions on 3D TEE were well correlated with balloon-stretched 2D dimensions. Two-dimensional TEE can underestimate the area of complex-shaped ASDs, which may result in residual right-to-left shunting. (J Am Soc Echocardiogr 2011;24:431-7.)
引用
收藏
页码:431 / 437
页数:7
相关论文
共 8 条
[1]
Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device - A three-dimensional transoesophageal echocardiographic reconstruction [J].
Acar, P ;
Saliba, Z ;
Bonhoeffer, P ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
EUROPEAN HEART JOURNAL, 2000, 21 (07) :573-581
[2]
Real-time three-dimensional transoesophageal echocardiography for guidance of atrial septal defect closures [J].
Balzer, Jan ;
Kuehl, Harald ;
Franke, Andreas .
EUROPEAN HEART JOURNAL, 2008, 29 (18) :2226-2226
[3]
CHAN KC, 1993, BRIT HEART J, V69, P52
[4]
FERREIRA SMAG, 1992, BRIT HEART J, V67, P316
[5]
Gatzoulis M.A., 2003, DIAGNOSIS MANAGEMENT
[6]
Handke M, 2001, Eur J Echocardiogr, V2, P46, DOI 10.1053/euje.2000.0064
[7]
Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure [J].
Lodato, Joseph A. ;
Cao, Qi Ling ;
Weinert, Lynn ;
Sugeng, Lissa ;
Lopez, John ;
Lang, Roberto M. ;
Hijazi, Ziyad M. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (04) :543-548
[8]
Application of Real-Time Three-Dimensional Transesophageal Echocardiography Using a Matrix Array Probe for Transcatheter Closure of Atrial Septal Defect [J].
Taniguchi, Manabu ;
Akagi, Teiji ;
Watanabe, Nobuhisa ;
Okamoto, Yoshio ;
Nakagawa, Koji ;
Kijima, Yasufumi ;
Toh, Norihisa ;
Ohtsuki, Shinichi ;
Kusano, Kengo ;
Sano, Shunji .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (10) :1114-1120