Determination of retention indices of polychlorobiphenyls by using other compounds detectable by electron-capture detection or selected polychlorobiphenyls as the reference series

被引:15
作者
Castello, G
Testini, G
机构
[1] Université di Geneva, Dipto. di Chim. e Chim. Industriale, 16146 Genova
关键词
retention indices; environmental analysis; polychlorinated biphenyls;
D O I
10.1016/0021-9673(96)00160-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The highest sensitivity to polychlorobiphenyls (PCBs) is offered by electron-capture detection (ECD), but the easy identification of individual congeners remains unresolved. Published retention data are of limited usefulness, as the lack of a uniform style and the dependence on the analysis conditions do not permit their general use. Retention index values of PCBs cannot be easily referred to n-alkanes, due to the very low response of these compounds to ECD, whereas other well detected reference series can be used: n-alkyl iodides were found useful for the determination of retention indices of the first congeners of the PCB series. Retention indices obtained by using selected DCMA (Dry Colour Manufacturers' Association) PCB reference mixtures can be directly used or converted to standard Kovats indices. A mixture of PCBs that shows a linear dependence of retention on the number of chlorine atoms on both isothermal and programmed-temperature analysis is suggested for reference purposes. Other methods and standard mixtures used for identification and quantitation purposes are reviewed and discussed.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 49 条
[1]  
ALBRO PW, 1977, J CHROMATOGR, V136, P147
[2]   QUANTITATIVE CHARACTERIZATION OF POLYCHLORINATED BIPHENYL MIXTURES (AROCLOR-1248, AROCLOR-1254 AND AROCLOR-1260) BY GAS-CHROMATOGRAPHY USING CAPILLARY COLUMNS [J].
ALBRO, PW ;
CORBETT, JT ;
SCHROEDER, JL .
JOURNAL OF CHROMATOGRAPHY, 1981, 205 (01) :103-111
[3]   QUANTITATIVE AND QUALITATIVE ANALYSIS OF POLYCHLORINATED BIPHENYLS BY GAS-LIQUID CHROMATOGRAPHY AND FLAME IONIZATION DETECTION .1. ONE TO 3 CHLORINE ATOMS [J].
ALBRO, PW ;
FISHBEIN, L .
JOURNAL OF CHROMATOGRAPHY, 1972, 69 (02) :273-&
[4]   ISOMER-SPECIFIC IDENTIFICATION OF PCB CONGENERS IN TECHNICAL MIXTURES AND ENVIRONMENTAL-SAMPLES BY HRGC-ECD AND HRGC-MSD [J].
BALLSCHMITER, K ;
SCHAFER, W ;
BUCHERT, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (03) :253-257
[5]  
BUDAHEGYI MV, 1983, J CHROMATOGR, V271, P213, DOI 10.1016/S0021-9673(00)80220-4
[6]  
BUSH B, 1982, J ASSOC OFF ANA CHEM, V65, P555
[7]   THE ROUTINE DETERMINATION OF PCBS IN WASTE AUTOMOTIVE ENGINE OILS [J].
CANALS, A ;
FORTEZA, R ;
CERDA, V .
CHROMATOGRAPHIA, 1992, 34 (1-2) :35-40
[8]   CORRELATIONS BETWEEN PHYSICAL PROPERTIES OF HALOGENATED ALKANES AND THEIR GAS-CHROMATOGRAPHIC BEHAVIOR ON POLAR AND NONPOLAR STATIONARY PHASES [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1973, 76 (02) :293-306
[9]   CORRELATIONS BETWEEN MOLECULAR STRUCTURE AND PHYSICAL PROPERTIES OF ALKYL IODIDES AND THEIR RETENTION INDICES [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1971, 58 (01) :127-&
[10]   GAS CHROMATOGRAPHY OF ALKYL IODIDES .2. INFLUENCE OF STRUCTURE ON RETENTION TIME AND SENSITIVITY TO ELECTRON CAPTURE DETECTOR [J].
CASTELLO, G ;
DAMATO, G .
JOURNAL OF CHROMATOGRAPHY, 1971, 54 (02) :157-&