Diagnostic performance of complete lower limb venous ultrasound in patients with clinically suspected acute pulmonary embolism

被引:49
作者
Elias, A
Colombier, D
Victor, G
Elias, M
Arnaud, C
Juchets, H
Ducassé, JL
Didier, A
Colin, C
Rousseau, H
Nguyen, F
Joffre, F
机构
[1] Rangueil Univ, Ctr Hosp, Dept Vasc Med, F-31403 Toulouse 04, France
[2] Rangueil Univ, Ctr Hosp, Dept Radiol, F-31403 Toulouse 04, France
[3] Rangueil Univ, Ctr Hosp, Dept Nucl Med, F-31403 Toulouse 04, France
[4] Rangueil Univ, Ctr Hosp, Dept Emergency, F-31403 Toulouse 04, France
[5] Rangueil Univ, Ctr Hosp, Dept Pulmonol, F-31403 Toulouse 04, France
[6] Rangueil Univ, Ctr Hosp, Dept Haemostasis, F-31403 Toulouse 04, France
[7] Hospices Civils Lyon, Dept Med Informat, Lyon, France
[8] Fac Med, Dept Epidemiol & Hlth Econ, Toulouse, France
关键词
pulmonary embolism; deep vein thrombosis; ultrasound/diagnosis;
D O I
10.1160/TH03-05-0278
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A limited ultrasound (US) confined to the popliteal and femoral veins is usually performed to detect deep vein thrombosis (DVT) in patients with clinically suspected acute pulmonary embolism (PE). Our objective was to assess the diagnostic accuracy of complete lower limb US examining both the proximal and distal veins in this setting. In this prospective study, 210 consecutive patients were included. Complete US was performed by independent operators and compared blindly with a reference strategy combining clinical probability, ventilation perfusion scan and pulmonary angiography to a three-month clinical follow-up. simultaniously, VIDAS D-dimer (DD) assay and helical computed tomography (HCT) of the lungs were assessed independently and blindly. PE was present in 74 patients (35%). Complete US detected DVT in 91 patients (43%), proximal in 51 and distal in 40. Sensitivity and specificity with a 0.95 confidence interval were respectively 0.93 [0.85 - 0.97] and 0.84 [0.77 - 0.89]. Limited US detected DVT in only 46 patients (22%). Sensitivity and specificity were respectively 0.55 [0.44 - 0.66] and 0.96 [0.92 - 0.98]. For DD they were 0.92 [0.83 - 0.96] and 0.24 [0.17 - 0.32] and for HCT 0.84 [0.73 - 0.90] and 0.87 [0.80 - 0.92]. Complete lower limb US has higher sensitivity and capacity to exclude PE than limited US, but a slightly lower specificity. Complete US results also compared favourably with those of HCT and DD.The utility of including this method in diagnostic strategies for PE needs to be assessed in cost-effectiveness analysis and in outcome studies.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
[1]  
Altman DG., 2013, STAT CONFIDENCE CONF
[2]   D-dimer for the diagnosis of venous thromboembolism [J].
Anderson, DR ;
Wells, PS .
CURRENT OPINION IN HEMATOLOGY, 2000, 7 (05) :296-301
[3]  
[Anonymous], 2000, Methods for Meta-Analysis in Medical Research
[4]   Spiral computed tomography is comparable to angiography for the diagnosis of pulmonary embolism [J].
Baile, EM ;
King, GG ;
Müller, NL ;
D'Yachkova, Y ;
Coche, EE ;
Paré, PD ;
Mayo, JR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (03) :1010-1015
[5]  
BARRELLIER MT, 1992, J MAL VASCUL, V17, P196
[6]   Serial duplex ultrasound examinations for deep vein thrombosis in patients with suspected pulmonary embolism [J].
Bendick, PJ ;
Glover, JL ;
Brown, OW ;
Ranval, TJ .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (05) :732-737
[7]   A 30-YEAR SURVEY OF PULMONARY-EMBOLISM VERIFIED AT AUTOPSY - AN ANALYSIS OF 1274 SURGICAL PATIENTS [J].
BERGQVIST, D ;
LINDBLAD, B .
BRITISH JOURNAL OF SURGERY, 1985, 72 (02) :105-108
[8]   PULMONARY-EMBOLISM FROM A VENOUS THROMBOSIS DISTAL TO THE POPLITEAL VEIN [J].
CHAPMAN, WHH ;
FOLEY, KT ;
LEE, YTM .
MILITARY MEDICINE, 1991, 156 (05) :252-254
[9]  
Christiansen F, 1997, Acta Radiol Suppl, V410, P1
[10]  