Non-touch fittings in hospitals:: a possible source of Pseudomonas aeruginosa and Legionella spp.

被引:62
作者
Halabi, M
Wiesholzer-Pittl, M
Schöberl, J
Mittermayer, H
机构
[1] Krakenhaus Barmherzigen Schwestern Ried Innkreis, Dept Pathol & Microbiol, A-4910 Ried, Austria
[2] Krakenhaus Barmherzigen Schwestern Ried Innkreis, Infect Control Team, A-4910 Ried, Austria
[3] Krankenhaus Elisabethinen Linz, Dept Hyg Microbiol & Trop Med, A-4020 Linz, Austria
关键词
non-touch fittings; hospital; nosocomial infection; Pseudomonas aeruginosa; Legionella spp;
D O I
10.1053/jhin.2001.1060
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Non-touch fittings are gradually becoming very common in the bathrooms and toilets of public facilities and restaurants. Hospitals and other healthcare facilities have recently started to install these types of,vater taps to lower water consumption, thus saving costs, and to prevent healthcare workers from touching the tap, thus promoting hygiene. This study analysed the bacteriological water quality of 38 non-touch water taps in different settings in a 450-bed secondary-care hospital in Upper Austria. Two different tap types were installed: 23 taps were without temperature selection and 15 were with temperature selection (cold and warm). A membrane filtration method was used, and the authors screened for both indicator organisms and Pseudomonas aeruginosa in 100 ml water samples. In 10 non-touch taps without temperature selection, the authors also screened for Legionella spp. in 500ml water samples. Seventy four percent of the taps without temperature selection and 7% of the taps with temperature selection showed contamination with P. aeruginosa (P < 0.001). None of the taps showed contamination with indicator organisms. Detailed analysis of the source of contamination revealed that the magnetic valve and the outlet itself were heavily contaminated, whereas the junction from the central pipe system was free of contamination. All 10 analysed taps showed contamination with Legionella spp. It was concluded that the local contamination of non-touch fittings is a result of the low amount of water that flows through the outlet, the low water pressure and the column of water, which is 'still -standing' and has a temperature of about 35 degreesC, thus providing nearly ideal growth conditions for P. aeruginosa. Additionally, the presence of materials such as rubber, PVC, etc. in the fittings enhances the adhesion of P. aeruginosa and thus the production of biofilms. In conclusion, the authors wish to encourage infection control teams to evaluate the use of non-touch fittings in hospitals, especially when they are installed in risk areas. (C) 2001 The Hospital Infection Society.
引用
收藏
页码:117 / 121
页数:5
相关论文
共 13 条
  • [1] Biofilms, infectious agents, and dental unit waterlines: a review
    Barbeau, J
    Gauthier, C
    Payment, P
    [J]. CANADIAN JOURNAL OF MICROBIOLOGY, 1998, 44 (11) : 1019 - 1028
  • [2] Multi-resistant Pseudomonas aeruginosa outbreak associated with contaminated tap water in a neurosurgery intensive care unit
    Bert, F
    Maubec, E
    Bruneau, B
    Berry, P
    Lambert-Zechovsky, N
    [J]. JOURNAL OF HOSPITAL INFECTION, 1998, 39 (01) : 53 - 62
  • [3] AEROSOLS CONTAINING LEGIONELLA-PNEUMOPHILA GENERATED BY SHOWER HEADS AND HOT-WATER FAUCETS
    BOLLIN, GE
    PLOUFFE, JF
    PARA, MF
    HACKMAN, B
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (05) : 1128 - 1131
  • [5] Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination
    Ferroni, A
    Nguyen, L
    Pron, B
    Quesne, G
    Brusset, MC
    Berche, P
    [J]. JOURNAL OF HOSPITAL INFECTION, 1998, 39 (04) : 301 - 307
  • [6] Nosocomial legionnaires' disease discovered in community hospitals following cultures of the water system: Seek and ye shall find
    Goetz, AM
    Stout, JE
    Jacobs, SL
    Fisher, MA
    Ponzer, RE
    Drenning, S
    Yu, VL
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1998, 26 (01) : 8 - 11
  • [7] CHARACTERIZATION OF MUCOID PSEUDOMONAS-AERUGINOSA STRAINS ISOLATED FROM TECHNICAL WATER-SYSTEMS
    GROBE, S
    WINGENDER, J
    TRUPER, HG
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1995, 79 (01): : 94 - 102
  • [8] Hospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial Legionnaires' disease:: A cohort study of 15 hospitals
    Kool, JL
    Bergmire-Sweat, D
    Butler, JC
    Brown, EW
    Peabody, DJ
    Massi, DS
    Carpenter, JC
    Pruckler, JM
    Benson, RF
    Fields, BS
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (12) : 798 - 805
  • [9] LUCK PC, 1993, ZBL HYG UMWELTMED, V193, P450
  • [10] RIBIERO CD, 1987, EPIDEMIOL INFECT, V3, P253