Selective reduction method for separate determination of inorganic and total mercury in mussel tissue by flow-injection cold vapor technique

被引:22
作者
Río-Segade, S [1 ]
Bendicho, C [1 ]
机构
[1] Univ Vigo, Fac Ciencias Quim, Dept Quim Analit & Alimentaria, Area Quim Analit, Vigo 36200, Spain
关键词
flow injection; cold vapor atomic absorption spectrometry; mussel samples; selective reduction; total mercury; inorganic mercury;
D O I
10.1006/eesa.1998.1753
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A flow-injection cold vapor atomic absorption spectrometry (FI-CV-AAS) method was developed to determine inorganic mercury and total mercury in mussel samples obtained from the Galicia coasts. The mussel samples were digested in a microwave oven using an HNO3/H2O2 mixture and then total mercury was determined using sodium borohydride as reducing agent. In a separate subsample, following ultrasonic extraction in hydrochloric acid medium, inorganic mercury was determined by selective reduction using stannous chloride in acid medium as reducing agent. The accuracy of the digestion method was checked by analyzing BCR Reference Material No. 278 Mussel Tissue (Mytilus edulis). There were no significant differences between the certified and found concentration values. As a certified reference material of mussel tissue containing both methylmercury and inorganic mercury was not available, recovery studies on mussel tissue samples spiked with inorganic mercury and methylmercury were done to check the reliability of the method. The results revealed that the mercury contained in mussel samples was methylmercury. (C) 1999 Academic Press.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 49 条
[1]  
ADELOJU SB, 1987, ANAL LETT, V20, P985
[2]  
Bortoli A, 1995, Ann Ist Super Sanita, V31, P359
[3]   At-line determination of mercury in process streams using atomic fluorescence spectrometry [J].
Brahma, NK ;
Corns, WT ;
Stockwell, PB ;
Ebdon, L ;
Evans, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (06) :611-616
[4]   Determination of mercury in urine by ET-AAS using complexation with dithizone and extraction with cyclohexane [J].
Burrini, C ;
Cagnini, A .
TALANTA, 1997, 44 (07) :1219-1223
[5]  
Campos RC, 1997, ATOM SPECTROSC, V18, P55
[6]   EFFECT OF PLASMA PRESSURE ON THE DETERMINATION OF MERCURY BY MICROWAVE-INDUCED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
COSTAFERNANDEZ, JM ;
PEREIROGARCIA, R ;
SANZMEDEL, A ;
BORDELGARCIA, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :649-653
[7]   Determination of mercury in dry fish samples by microwave digestion and flow injection analysis system cold vapor atomic absorption spectrometry [J].
dePaz, LA ;
Alegria, A ;
Barbera, R ;
Farre, R ;
Lagarda, MJ .
FOOD CHEMISTRY, 1997, 58 (1-2) :169-172
[8]   Simultaneous radiochemical neutron activation analysis of iodine, uranium and mercury in biological and environmental samples [J].
Dermelj, M ;
Byrne, AR .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 216 (01) :13-18
[9]   Determination of mercury in fluorescent lamp cullet by slurry sampling electrothermal atomic absorption spectrometry [J].
Dobrowolski, R ;
Mierzwa, J .
ANALYST, 1996, 121 (07) :897-900
[10]   Long-term sampling system for the measurement of ambient air concentrations of mercury at a contaminated site [J].
Dorr, G ;
Deinzer, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :117-120