Use of pulse transit time to distinguish respiratory events from tidal breathing in sleeping children

被引:27
作者
Foo, JYA
Wilson, SJ
Bradley, AP
Williams, GR
Harris, MA
Cooper, DM
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Mater Misericordiae Childrens Hosp, Dept Resp & Sleep Med, Brisbane, Qld, Australia
关键词
central sleep apnea; hypopnea; noninvasive technique; obstructive sleep apnea; pediatrics; pulse transit time; upper airway;
D O I
10.1378/chest.128.4.3013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: Currently, esophageal pressure monitoring is the "gold standard" measure for inspiratory efforts, hut its invasive nature necessitates a better tolerated and noninvasive method to be used on children. Pulse transit time (PTT) has demonstrated its potential as a noninvasive surrogate marker for inspiratory efforts. The principle velocity determinant of PTT is the change in stiffness of the arterial wall and is inversely correlated to BP. Moreover, PTT has been shown to identify changes in inspiratory effort via the BP fluctuations induced by negative pleural pressure swings. In this study, the capability of PTT to classify respiratory, events during sleep as either central or obstructive in nature was investigated. Setting and participants: PTT measure was used in adjunct to routine overnight polysomnographic studies performed on 33 children (26 boys and 7 girls; mean +/- SD age, 6.7 +/- 3.9 years). The accuracy of PTT measurements was then evaluated against scored corresponding respiratory events in the polysomnography recordings. Results: Three hundred thirty-four valid respiratory events occurred and were analyzed. One hundred twelve obstructive events (OEs) showed a decrease in mean PTT over a 10-sample window that had a probability of being correctly ranked below the baseline PTT during tidal breathing of 0.92 (p < 0.005); 222 central events (CEs) showed a decrease in the variance of PTT over a 10-sample window that had a probability of being ranked below the baseline PTT of 0.94 (p < 0.005). This indicates that, at a sensitivity of 0.90, OEs can be detected with a specificity of 0.82 and CEs can be detected with a specificity of 0.80. Conclusions: PTT is able to categorize CEs and OEs accordingly in the absence of motion artifacts, including hypopneas. Hence, PTT shows promise to differentiate respiratory, events accordingly and can be an important diagnostic tool in pediatric respiratory sleep studies.
引用
收藏
页码:3013 / 3019
页数:7
相关论文
共 31 条
[1]   Differentiating obstructive and central sleep respiratory events through pulse transit time [J].
Argod, J ;
Pépin, JL ;
Lévy, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (06) :1778-1783
[2]   Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events [J].
Argod, J ;
Pépin, JL ;
Smith, RP ;
Lévy, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :87-93
[3]   EFFECTS OF AGING ON CHANGING ARTERIAL COMPLIANCE AND LEFT-VENTRICULAR LOAD IN A NORTHERN CHINESE URBAN-COMMUNITY [J].
AVOLIO, AP ;
CHEN, SG ;
WANG, RP ;
ZHANG, CL ;
LI, MF ;
OROURKE, MF .
CIRCULATION, 1983, 68 (01) :50-58
[4]  
BRADLEY TD, 1992, CLIN CHEST MED, V13, P493
[5]   Sleep apnea and heart failure - Part II: Central sleep apnea [J].
Bradley, TD ;
Floras, JS .
CIRCULATION, 2003, 107 (13) :1822-1826
[6]   Comparative hemodynamic effects of periodic obstructive and simulated central apneas in sedated pigs [J].
Chen, L ;
Scharf, SM .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (02) :485-494
[7]   Effects of esophageal pressure monitoring on sleep architecture [J].
Chervin, RD ;
Aldrich, MS .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (03) :881-885
[8]   Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitis [J].
Cheung, YF ;
Brogan, PA ;
Pilla, CB ;
Dillon, MJ ;
Redington, AN .
ARCHIVES OF DISEASE IN CHILDHOOD, 2002, 87 (04) :348-351
[9]   Principal component analysis of chest wall movement in selected pathologies [J].
Ferrigno G. ;
Carnevali P. .
Medical and Biological Engineering and Computing, 1998, 36 (4) :445-451
[10]   Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement [J].
Foo J.Y.A. ;
Wilson S.J. ;
Williams G.R. ;
Harris M. ;
Cooper D.M. .
Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (4) :165-173