Quality control of equipment in home mechanical ventilation: a European survey

被引:50
作者
Farre, R
Lloyd-Owen, SJ
Ambrosino, N
Donaldson, G
Escarrabill, J
Fauroux, B
Robert, D
Schoenhofer, B
Simonds, A
Wedzicha, JA
机构
[1] St Bartholomews Hosp, Acad Unit Resp Med, London EC1A 7BE, England
[2] Univ Barcelona, Unitat Biofis & Bioengn, Fac Med, Inst Invest Biomed August Pi Sunyer, Barcelona, Spain
[3] Hosp Univ Bellvitge, Unitat Funct Interdisciplinaria Sociosanit Resp, Lhospitalet De Llobregat, Spain
[4] Royal London Sch Med & Dent, London, England
[5] Royal Brompton & Harefield NHS Trust, London, England
[6] Univ Hosp Pisa, Pisa, Italy
[7] Hosp Armand Trousseau, Paris, France
[8] Assoc Lyonnaise Logist Hosp, Lyon, France
[9] Klinikum Hannover, Oststadkrankenhaus, Hannover, Germany
关键词
chronic respiratory failure; healthcare assessment; home-care monitoring; home therapy; noninvasive ventilation;
D O I
10.1183/09031936.05.00066904
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Quality control of the equipment used in home mechanical ventilation is necessary in order to ensure that patients safely and accurately receive the prescribed ventilatory support. The aim of this study was to carry out a survey on the quality-control procedures in different centres and countries. The survey was carried out in the context of a European Commission Concerted Action covering 16 European countries. The study was extensive and detailed, involving 326 centres, which provided home ventilation to > 20,000 patients. The survey showed that: 1) ventilator servicing was mainly carried out by external companies (62% of centres), with a servicing frequency ranging 3-12 months; 2) interaction between servicing companies and prescribers was limited (only 61% of centres were always informed of major incidents); 3) participation of centres in equipment quality control was poor (only 56% of centres assessed that patients/caregivers correctly cleaned/maintained the ventilator); and 4) centres were insufficiently aware of vigilance systems (only 23% of centres). Moreover, the data showed considerable inter- and intra-country differences. The size of the centre was an important determinant of many of these quality-control aspects. This survey provides information that will enable the European Commission Concerted Action to formulate recommendations on procedures for home-ventilator quality control.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 40 条
[1]
Nasal continuous positive airway pressure devices do not maintain the set pressure dynamically when tested under simulated clinical conditions [J].
Bacon, JP ;
Farney, RJ ;
Jensen, RL ;
Waker, JM ;
Cloward, TV .
CHEST, 2000, 118 (05) :1441-1449
[2]
Reduction of hospital utilization in patients with chronic obstructive pulmonary disease -: A disease-specific self-management intervention [J].
Bourbeau, J ;
Julien, M ;
Maltais, F ;
Rouleau, M ;
Beaupré, A ;
Bégin, R ;
Renzi, P ;
Nault, D ;
Borycki, E ;
Schwartzmann, K ;
Singh, R ;
Collet, JP .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (05) :585-591
[3]
NONINVASIVE AND DOMICILIARY VENTILATION - POSITIVE PRESSURE TECHNIQUES [J].
BRANTHWAITE, MA .
THORAX, 1991, 46 (03) :208-212
[4]
Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube [J].
Cannon, ML ;
Cornell, J ;
Tripp-Hamel, DS ;
Gentile, MA ;
Hubble, CL ;
Meliones, JN ;
Cheifetz, IM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (06) :2109-2112
[5]
Chatmongkolchart S, 2001, Respir Care, V46, P666
[6]
Caregivers of long-term ventilator patients - Physical and psychological outcomes [J].
Douglas, SL ;
Daly, BJ .
CHEST, 2003, 123 (04) :1073-1081
[7]
*EUR COMM, 2002, REP FUNCT MED DEV DI
[8]
*EUR COMM, LIST VIG CONT POINTS
[9]
*EUR STAND COMM, 2001, LUNG VENT MED US 2
[10]
European Parliament and Council, 1993, OFFICIAL J L, V169, P1