Nosocomial Legionnaires' disease - strategies for prevention

被引:12
作者
Ruef, C [1 ]
机构
[1] Univ Zurich Hosp, Hosp Epidemiol Unit HAL 14C, Div Infect Dis & Hosp Epidemiol, CH-8091 Zurich, Switzerland
关键词
environment; Legionella; nosocomial; prevention; risk assessment; water;
D O I
10.1016/S0167-7012(98)00042-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Colonization of water systems by Legionella spp. is ubiquitous in hospitals throughout the world. Nevertheless, the consequences of this situation are variable. In some hospitals nosocomial pneumonia caused by Legionella pneumophila is a rare event, whereas this pathogen causes epidemics in others and results in significant morbidity and mortality. In hospital wards where immunosuppressed patients are treated, hot water systems should ideally be free of Legionella contamination. Risk assessment for this disease forms the basis for the institution of control measures. Detection and quantification of Legionella spp. in the environment, in particular in the hospital water distribution system is one of the cornerstones of risk assessment. Despite the existence of guidelines for the prevention of this nosocomial infection, many methodical and technical aspects of surveillance and prevention are not standardized. This review, summarizes the current state-of-the-art regarding these aspects and points out important areas which require further study. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:81 / 91
页数:11
相关论文
共 51 条
[1]   FACTORS CONTRIBUTING TO THE CONTAMINATION OF HOSPITAL WATER DISTRIBUTION-SYSTEMS BY LEGIONELLAE [J].
ALARY, M ;
JOLY, JR .
JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (03) :565-569
[2]   NOSOCOMIAL LEGIONNAIRES-DISEASE CAUSED BY AEROSOLIZED TAP WATER FROM RESPIRATORY DEVICES [J].
ARNOW, PM ;
CHOU, T ;
WEIL, D ;
SHAPIRO, EN ;
KRETZSCHMAR, C .
JOURNAL OF INFECTIOUS DISEASES, 1982, 146 (04) :460-467
[3]  
BEST M, 1983, LANCET, V2, P307
[4]   LEGIONELLA-PNEUMOPHILA - COMPARISON OF ISOLATION FROM WATER SPECIMENS BY CENTRIFUGATION AND FILTRATION [J].
BRINDLE, RJ ;
STANNETT, PJ ;
CUNLIFFE, RN .
EPIDEMIOLOGY AND INFECTION, 1987, 99 (02) :241-247
[5]   Prevention and control of legionellosis [J].
Butler, JC ;
Fields, BS ;
Breiman, RF .
INFECTIOUS DISEASES IN CLINICAL PRACTICE, 1997, 6 (07) :458-464
[6]  
*CDC, 1997, MMWR-MORBID MORTAL W, V46, P74
[7]  
*CDC, 1997, MMWR-MORBID MORTAL W, V46, P54
[8]  
*CDC, 1997, MMWR-MORBID MORTAL W, V46, P28
[9]   ROLE OF STAGNATION AND OBSTRUCTION OF WATER-FLOW IN ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM HOSPITAL PLUMBING [J].
CIESIELSKI, CA ;
BLASER, MJ ;
WANG, WLL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (05) :984-987
[10]   GROWTH OF LEGIONELLA-PNEUMOPHILA IN ACANTHAMOEBA-CASTELLANII ENHANCES INVASION [J].
CIRILLO, JD ;
FALKOW, S ;
TOMPKINS, LS .
INFECTION AND IMMUNITY, 1994, 62 (08) :3254-3261