Application of 3D printed customized external fixator in fracture reduction

被引:81
作者
Qiao, Feng [1 ]
Li, Dichen [2 ,3 ]
Jin, Zhongmin [3 ,4 ]
Gao, Yongchang [3 ]
Zhou, Tao [3 ]
He, Jinlong [1 ]
Cheng, Li [1 ]
机构
[1] Xi An Jiao Tong Univ, Hong Hui Hosp, Dept Orthopaed, Coll Med, Xian 710054, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthopaed, Xian 710004, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Mech Engn, State Key Lab Mfg Syst Engn, Xian 710054, Shaanxi, Peoples R China
[4] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 06期
关键词
3D printing; Computer-assisted surgery; Long bone fracture; Closed reduction; External fixator; DISTAL FEMORAL FRACTURES; TIBIAL-SHAFT FRACTURES; DIAPHYSEAL; NAVIGATION; MALALIGNMENT; EVOLUTION; TRIAL;
D O I
10.1016/j.injury.2015.01.020
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Introduction: Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. Materials and methods: We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. Results: Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21 degrees(+/- 0.24), angulation of 1.84 degrees(+/- 0.28), and lateral displacement of 2.22 mm(+/- 0.62). Conclusions: A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1150 / 1155
页数:6
相关论文
共 35 条
[1]
ARNESON TJ, 1988, CLIN ORTHOP RELAT R, P188
[2]
Surgeon's preferences for the operative treatment of fractures of the tibial shaft - An international survey [J].
Bhandari, M ;
Guyatt, GH ;
Swiontkowski, MF ;
Tornetta, P ;
Hanson, B ;
Weaver, B ;
Sprague, S ;
Schemitsch, EH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11) :1746-1752
[3]
Randomized Trial of Reamed and Unreamed Intramedullary Nailing of Tibial Shaft Fractures [J].
Bhandari, Mohit ;
Guyatt, Gordon ;
Tornetta, Paul, III ;
Schemitsch, Emil H. ;
Swiontkowski, Marc ;
Sanders, David ;
Walter, Stephen D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) :2567-2578
[4]
Bone tissue engineering using 3D printing [J].
Bose, Susmita ;
Vahabzadeh, Sahar ;
Bandyopadhyay, Amit .
MATERIALS TODAY, 2013, 16 (12) :496-504
[5]
External fixation of diaphyseal fractures of the tibia [J].
Checketts, RG ;
Young, CF .
CURRENT ORTHOPAEDICS, 2003, 17 (03) :176-189
[6]
Three-dimensional measurement of femoral antetorsion: comparison to a conventional radiological method [J].
Citak, Musa ;
Oszwald, Markus ;
O'Loughlin, Padhraig F. ;
Citak, Mustafa ;
Kendoff, Daniel ;
Huefner, Tobias ;
Krettek, Christian .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (04) :513-518
[7]
Citak Mustafa, 2009, Technol Health Care, V17, P25, DOI 10.3233/THC-2009-0529
[8]
EFFECTS OF AXIAL DYNAMIZATION ON BONE HEALING [J].
EGGER, EL ;
GOTTSAUNERWOLF, F ;
PALMER, J ;
ARO, HT ;
CHAO, EYS .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1993, 34 (02) :185-192
[9]
Correction of tibial malunion and nonunion with six-axis analysis deformity correction using the Taylor spatial frame [J].
Feldman, DS ;
Shin, SS ;
Madan, S ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (08) :549-554
[10]
Friedlaender GE, 2001, J BONE JOINT SURG AM, V83A, pS151