Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT

被引:133
作者
Jeong, YJ
Lee, KS
Jeong, SY
Chung, MJ
Shim, SS
Kim, H
Kwon, OJ
Kim, S
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Med,Div Pulm & Crit Care, Seoul 135710, South Korea
[4] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Biostat Unit, Seoul 135710, South Korea
关键词
D O I
10.1148/radiol.2372041549
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To prospectively assess the accuracy of combined wash-in and washout characteristics at dynamic contrast material-enhanced multi-detector row computed tomography (CT) in distinguishing benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. The study included 107 patients (62 men, 45 women; mean age, 55 years; range, 22-81 years) with a solitary pulmonary nodule. After unenhanced CT (2.5-mm collimation) scans were obtained, dynamic CT was performed by using a helical technique (series of images obtained throughout the nodule, with 2.5-mm collimation, at 30, 60, 90, and, 120 seconds and 4, 5, 9, 12, and 15 minutes) after intravenous injection of contrast medium (1120 mL). Tissue diagnosis was made in 70 nodules, and follow-up images showed benignancy in the remaining 17 (no change in size, n = 32; decrease in size, n = 5). CT findings were analyzed in terms of wash-in and washout of contrast medium. Sensitivity, specificity, and accuracy for malignant nodules were calculated by considering both the wash-in and washout characteristics at dynamic CT. RESULTS: There were 49 malignant,land 58 benign nodules. When diagnostic criteria for malignancy of both wash-in of 25 HU or greater and washout of 5-31 HU were applied, sensitivity, specificity, and accuracy for malignancy were 94% (46 of 49 nodules), 90% (52 of 58 nodules), and 92% (98 of 107 nodules), respectively. Of 58 benign nodules, 27 showed less than 25 HU wash-in, 14 showed persistent contrast enhancement without washout and with wash-in of 25 HU or greater, and 11 showed washout greater than 31 HU and wash-in of 25 HU or greater. CONCLUSION: Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multi-detector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules. (c) RSNA, 2005.
引用
收藏
页码:675 / 683
页数:9
相关论文
共 32 条
[1]
Resection of pulmonary nodules using video-assisted thoracic surgery [J].
Bernard, A ;
Azorin, J ;
Bellenot, F ;
Bonnette, P ;
Brichon, PY ;
Brutus, P ;
Chapelier, A ;
Charpentier, R ;
Dahan, M ;
Dujon, A ;
Escande, G ;
Faillon, MJ ;
Giudicelli, R ;
Grosdidier, G ;
Grunenwald, D ;
Jancovici, R ;
Joyeux, A ;
Meriot, S ;
Monteau, M ;
Moreau, JL ;
Moreau, P ;
Mouroux, J ;
Pouliquen, E ;
Raut, Y ;
Regnard, JF ;
Riquet, M ;
Valverde, JP ;
Velly, JF ;
Wilhm, JM .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :202-204
[2]
Adrenal masses: Characterization with delayed contrast-enhanced CT [J].
Boland, GW ;
Hahn, PF ;
Pena, C ;
Mueller, PR .
RADIOLOGY, 1997, 202 (03) :693-696
[3]
Adrenal masses: Characterization with combined unenhanced and delayed enhanced CT [J].
Caoili, EM ;
Korobkin, M ;
Francis, IR ;
Cohan, RH ;
Platt, JF ;
Dunnick, NR ;
Raghupathi, KI .
RADIOLOGY, 2002, 222 (03) :629-633
[4]
DEFFEBACH ME, 1987, AM REV RESPIR DIS, V135, P463
[5]
DIAGNOSTIC EFFICACY OF PET-FDG IMAGING IN SOLITARY PULMONARY NODULES - POTENTIAL ROLE IN EVALUATION AND MANAGEMENT [J].
DEWAN, NA ;
GUPTA, NC ;
REDEPENNING, LS ;
PHALEN, JJ ;
FRICK, MP .
CHEST, 1993, 104 (04) :997-1002
[6]
Using a saline chaser to decrease contrast media in abdominal CT [J].
Dorio, PJ ;
Lee, FT ;
Henseler, KP ;
Pilot, M ;
Pozniak, MA ;
Winter, TC ;
Shock, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) :929-934
[7]
Furukawa H, 1996, HEPATO-GASTROENTEROL, V43, P1230
[8]
Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis [J].
Jung, KJ ;
Lee, KS ;
Kim, SY ;
Kim, TS ;
Pyeun, YS ;
Lee, JY .
INVESTIGATIVE RADIOLOGY, 2000, 35 (09) :557-563
[9]
MAJOR PULMONARY RESECTION FOR SUSPECTED BUT UNCONFIRMED MALIGNANCY [J].
KEAGY, BA ;
STAREK, PJK ;
MURRAY, GF ;
BATTAGLINI, JW ;
LORES, ME ;
WILCOX, BR .
ANNALS OF THORACIC SURGERY, 1984, 38 (04) :314-316
[10]
EXTRAVASCULAR CONTRAST MATERIAL - MAJOR COMPONENT OF CONTRAST ENHANCEMENT [J].
KORMANO, M ;
DEAN, PB .
RADIOLOGY, 1976, 121 (02) :379-382