Report on the development of a procedure to prevent placement of feeding tubes into the lungs using end-tidal CO2 measurements

被引:55
作者
Burns, SM [1 ]
Carpenter, R [1 ]
Truwit, JD [1 ]
机构
[1] Univ Virginia Hlth Syst, Charlottesville, VA 22908 USA
关键词
intubation; enteral nutrition; gastrointestinal feedings; capnography; enteral tube insertion;
D O I
10.1097/00003246-200105000-00004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine the accuracy of a technique using capnography to prevent inadvertent placement of small-bore feeding tubes and Salem sump tubes into the lungs. Setting: Twelve-bed medical intensive care unit (MICU) in a 557-bed teaching hospital. Patients: A total of 25 ventilated adult MICU patients were studied-5 in phase 1 and 20 in phase 2. Design: Phase 1 tested the ability of the end-tidal CO2 (ETCO2) monitor to detect flow (and thus accurately detect CO2) through small-bore feeding tubes. A small-bore feeding tube, with stylet in place, was placed 5 cm through the top of the tracheostomy tube ventilator adapter in five consecutive patients. The distal end of the feeding tube was attached to the ETCO2 monitor. The ETCO2 level and waveform were assessed and recorded. Because CO2 waveforms were successfully detected, a convenience sample of 20 adult MICU patients who were having feeding tubes placed (13 Salem sump tubes, 7 small-bore feeding tubes) was then studied. The technique consisted of attaching the ETCO2 monitor to the tubes and observing the ETCO2 waveform throughout placement. Results: The study hypothesis was supported. Of the seven small-bore feeding tubes tested, all were successfully placed on initial insertion. Placement was confirmed by absence of an ETCO2 waveform and by radiograph. Of the 13 Salem sump tubes, 9 were placed successfully on first attempt and confirmed by absence of CO2 and by air bolus and aspiration of stomach contents. ETCO2 waveforms were detected with insertion of four of the Salem sump tubes; the tubes were immediately withdrawn, and placement was reattempted until successful. Conclusions: The technique described is a simple, cost-effective method of assuring accurate gastric tube placement in critically ill patients.
引用
收藏
页码:936 / 939
页数:4
相关论文
共 9 条
[1]  
DOBRANOWSKI J, 1992, J CAN ASSOC RADIOL, V43, P35
[2]   PULMONARY COMPLICATIONS FROM NASOENTERAL FEEDING TUBE INSERTION IN AN INTENSIVE-CARE UNIT - INCIDENCE AND PREVENTION [J].
HARRIS, MR ;
HUSEBY, JS .
CRITICAL CARE MEDICINE, 1989, 17 (09) :917-919
[3]  
METHENY N, 1993, NURS RES, V42, P324
[4]  
METHENY N, 1990, NURS RES, V39, P262
[5]   pH and concentrations of pepsin and trypsin in feeding tube aspirates as predictors of tube placement [J].
Metheny, NA ;
Stewart, BJ ;
Smith, L ;
Yan, H ;
Diebold, M ;
Clouse, RE .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1997, 21 (05) :279-285
[6]   pH and concentration of bilirubin in feeding tube aspirates as predictors of tube placement [J].
Metheny, NA ;
Stewart, BJ ;
Smith, L ;
Yan, H ;
Diebold, M ;
Clouse, RE .
NURSING RESEARCH, 1999, 48 (04) :189-197
[7]   PNEUMOTHORAX DUE TO NASOGASTRIC FEEDING TUBES - REPORT OF 4 CASES, REVIEW OF THE LITERATURE, AND RECOMMENDATIONS FOR PREVENTION [J].
ROUBENOFF, R ;
RAVICH, WJ .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (01) :184-188
[8]  
STJOHN RE, 1996, PROTOCOLS PRACTICE N
[9]   PNEUMOTHORAX COMPLICATING SMALL-BORE FEEDING TUBE PLACEMENT [J].
WENDELL, GD ;
LENCHNER, GS ;
PROMISLOFF, RA .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (03) :599-602