Experimental study of intracranial hematoma detection with flat panel detector C-arm CT

被引:16
作者
Arakawa, H. [1 ]
Marks, M. P. [1 ,3 ]
Do, H. M. [1 ,3 ]
Bouley, D. M. [2 ]
Strobel, N. [1 ,4 ]
Moore, T. [1 ,4 ]
Fahrig, R. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Dept Comparat Med, Stanford, CA 94305 USA
[3] Stanford Univ, Med Ctr, Dept Neurosurg, Stanford, CA 94305 USA
[4] Siemens Med Solut, Erlangen, Germany
关键词
D O I
10.3174/ajnr.A0898
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Intracranial hemorrhage is a commonly acknowledged complication of interventional neuroradiology procedures, and the ability to image hemorrhage at the time of the procedure would be very beneficial. A new C-arm system with 3D functionality extends the capability of C-arm imaging to include soft-tissue applications by facilitating the detection of low-contrast objects. We evaluated its ability to detect small intracranial hematomas in a swine model. MATERIALS AND METHODS: Intracranial hematomas were created in 7 swine by autologous blood injection of various hematocrits (19%-37%) and volumes (1.5-5 mL). Four animals received intravascular contrast before obtaining autologous blood (group 1), and 3 did not (group 2). We scanned each animal by using the C-arm CT system, acquiring more than 500 images during a 20-second rotation through more than 200 degrees. Multiplanar reformatted images with isotropic resolution were reconstructed on the workstation by using product truncation, scatter, beam-hardening, and ring-artifact correction algorithms. The brains were harvested and sliced for hematoma measurement and compared with imaging findings. RESULTS: Five intracranial hematomas were created in group 1 animals, and all were visualized. Six were created in group 2, and 3 were visualized. One nonvisualized hematoma was not confirmed at necropsy. All the others in both groups were confirmed. In group 1 (with contrast), small hematomas were detectable even when the hematocrit was 19%-20%. In group 2 (without contrast) C-arm CT was able to detect small hematomas (< 1.0 cm(2)) created with hematocrits of 29%-37%. The area of hematoma measured from the C-arm CT data was, on average, within 15% of the area measured from harvested brain. CONCLUSIONS: The image quality obtained with this implementation of C-arm CT was sufficient to detect experimentally created small intracranial hematomas. This capability should provide earlier detection of hemorrhagic complications that may occur during neurointerventional procedures.
引用
收藏
页码:766 / 772
页数:7
相关论文
共 40 条
[1]  
Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
[2]   Potential of software-based scatter corrections in cone-beam volume CT [J].
Bertram, M ;
Wiegert, J ;
Rose, G .
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 :259-270
[3]  
Cohen WA., 1992, NEUROIMAG CLIN N AM, V2, P75
[4]   A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION [J].
DEFRISE, M ;
CLACK, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) :186-195
[5]  
Deinsberger W, 1996, NEUROL RES, V18, P475
[6]   Magnitude and effects of x-ray scatter in a 256-slice CT scanner [J].
Endo, Masahiro ;
Mori, Shinichiro ;
Tsunoo, Takanori ;
Miyazaki, Hiroaki .
MEDICAL PHYSICS, 2006, 33 (09) :3359-3368
[7]   Dose and image quality for a cone-beam C-arm CT system [J].
Fahrig, Rebecca ;
Dixon, Robert ;
Payne, Thomas ;
Morin, Richard L. ;
Ganguly, Arundhuti ;
Strobel, Norbert .
MEDICAL PHYSICS, 2006, 33 (12) :4541-4550
[8]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[9]   Practical x-ray scatter measurements for volume CT detector design [J].
Fox, TR ;
Nisius, DT ;
Aradate, H ;
Saito, Y .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :808-814
[10]   3D cone-beam CT reconstruction for circular trajectories [J].
Grass, M ;
Köhler, T ;
Proksa, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :329-347