Closure of large intrathoracic airway defects using extrathoracic muscle flaps

被引:50
作者
Meyer, AJH [1 ]
Krueger, T [1 ]
Lepori, D [1 ]
Dusmet, M [1 ]
Aubert, JD [1 ]
Pasche, P [1 ]
Ris, HB [1 ]
机构
[1] Univ Lausanne, Thorac Surg Unit, Dept Radiol, Div Pulm Med,CHUV, CH-1011 Lausanne, Switzerland
关键词
D O I
10.1016/S0003-4975(03)01462-0
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background. Prospective assessment of pedicled extrathoracic muscle flaps for the closure of large intrathoracic airway defects after noncircumferential resection in situations where an end-to-end reconstruction seemed risky (defects of > 4-cm length, desmoplastic reactions after previous infection or radiochemotherapy). Methods. From 1996 to 2001, 13 intrathoracic muscle transpositions (6 latissimus dorsi and 7 serratus anterior muscle flaps) were performed to close defects of the intrathoracic airways after noncircumferential resection for tumor (n = 5), large tracheoesophageal fistula (n = 2), delayed tracheal injury (n = 1) and bronchopleural fistula (n = 5). In 2 patients, the extent of the tracheal defect required reinforcement of the reconstruction by use of a rib segment embedded into the muscle flap followed by temporary tracheal stenting. Patient follow-up was by clinical examination bronchoscopy and biopsy, pulmonary function tests, and dynamic virtual bronchoscopy by computed tomographic (CT) scan during inspiration and expiration. Results. The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. They were all successfully closed using muscle flaps with no mortality and all patients were extubated within 24 hours. Bronchoscopy revealed epithelialization of the reconstructions without dehiscence, stenosis, or recurrence of fistulas. The flow-volume loop was preserved in all patients and dynamic virtual bronchoscopy revealed no significant difference in the endoluminal cross surface areas of the airway between inspiration and expiration above (45 +/- 21 mm(2)), at the site (76 +/- 23 mm(2)) and below the reconstruction (65 +/- 40 mm(2)). Conclusions. Intrathoracic airway defects of up to 50% of the circumference may be repaired using extrathoracic muscle flaps when an end-to-end reconstruction is not feasible. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:397 / 404
页数:8
相关论文
共 34 条
[1]
Abrashanoff X., 1911, ZENTRALBL CHIR, V38, P186
[2]
ALLEN MS, 1992, CHEST SURG CLIN N AM, V2, P823
[3]
USE OF PLEURA, AZYGOS VEIN, PERICARDIUM, AND MUSCLE FLAPS IN TRACHEOBRONCHIAL SURGERY [J].
ANDERSON, TM ;
MILLER, JI .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :729-733
[4]
INTRATHORACIC MUSCLE FLAPS - AN ACCOUNT OF THEIR USE IN THE MANAGEMENT OF 100 CONSECUTIVE PATIENTS [J].
ARNOLD, PG ;
PAIROLERO, PC .
ANNALS OF SURGERY, 1990, 211 (06) :656-662
[5]
Evaluation of airway obstruction using virtual endoscopy [J].
Burke, AJ ;
Vining, DJ ;
McGuirt, WF ;
Postma, G ;
Browne, JD .
LARYNGOSCOPE, 2000, 110 (01) :23-29
[6]
Three-dimensional computed tomography bronchoscopy using clinical datasets: a comparison with fibreoptic bronchoscopy [J].
Chinn, RJS ;
Yang, GZ ;
Congleton, J ;
Mellor, J ;
Geddes, DM ;
Hansell, DM .
CLINICAL RADIOLOGY, 1997, 52 (11) :830-836
[7]
A PROCEDURE FOR MANAGEMENT OF POSTPNEUMONECTOMY EMPYEMA [J].
CLAGETT, OT ;
GERACI, JE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1963, 45 (02) :141-&
[8]
Deschamps C, 1996, Chest Surg Clin N Am, V6, P519
[9]
Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients [J].
Ferretti, GR ;
Knoplioch, J ;
Bricault, I ;
Brambilla, C ;
Coulomb, M .
EUROPEAN RADIOLOGY, 1997, 7 (06) :854-859
[10]
Gaissert Henning A, 2003, Chest Surg Clin N Am, V13, P247, DOI 10.1016/S1052-3359(03)00019-X