Comparison of thromboelastometry (ROTEM®) with standard plasmatic coagulation testing in paediatric surgery

被引:203
作者
Haas, T. [1 ]
Spielmann, N. [1 ]
Mauch, J. [1 ]
Madjdpour, C. [1 ]
Speer, O. [2 ,3 ,4 ]
Schmugge, M. [2 ]
Weiss, M. [1 ]
机构
[1] Univ Childrens Hosp Zurich, Dept Anaesthesia, CH-8032 Zurich, Switzerland
[2] Univ Childrens Hosp Zurich, Dept Haematol, CH-8032 Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Childrens Res Ctr, CH-8032 Zurich, Switzerland
[4] Univ Zurich, Inst Physiol, Zurich Ctr Integrat Human Physiol, CH-8057 Zurich, Switzerland
关键词
blood; coagulation; complication; coagulopathy; measurement techniques; thrombelastograph; ORTHOTOPIC LIVER-TRANSPLANTATION; FIBRINOGEN CONCENTRATE; BLOOD-LOSS; MASSIVE HEMORRHAGE; REFERENCE RANGES; TRAUMA PATIENTS; MAJOR TRAUMA; MANAGEMENT; COAGULOPATHY; TRANSFUSION;
D O I
10.1093/bja/aer342
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background. Thromboelastometry (ROTEM (R)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests. Methods. Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen level] and ROTEM (R) analyses (InTEM, ExTEM, and FibTEM) were performed simultaneously by trained hospital laboratory staff. Results. A total of 288 blood samples from 50 subjects were analysed. While there was a poor correlation between PT and aPTT to ExTEM clotting time (CT) and InTEM CT, respectively, a good correlation was detected between PT and aPTT to clot formation time, and a very good correlation between fibrinogen level and FibTEM assay (r = 0.882, P < 0.001). Notably, 64% of PT and 94% of aPTT measurements were outside the reference range, while impaired CT was observed in 13% and 6.3%, respectively. Standard coagulation test results were available after a median of 53 min [inter-quartile range (IQR): 45-63 min], whereas 10 min values of ROTEM (R) results were available online after 23 min (IQR: 21-24 min). Conclusions. PT and aPTT cannot be interchangeably used with ROTEM (R) CT. Based on the results of ROTEM (R), recommended thresholds for PT and aPTT might overestimate the need for coagulation therapy. A good correlation was found between the fibrinogen level and the FibTEM assay. In addition, ROTEM (R) offered faster turnaround times.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 37 条
[1]
Amer Soc Anesthesiologists Task Fo, 2006, ANESTHESIOLOGY, V105, P198
[2]
ANDREW M, 1990, AM J PEDIAT HEMATOL, V12, P95
[3]
Finding the optimal concentration range for fibrinogen replacement after severe haemodilution: an in vitro model [J].
Bolliger, D. ;
Szlam, F. ;
Molinaro, R. J. ;
Rahe-Meyer, N. ;
Levy, J. H. ;
Tanaka, K. A. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (06) :793-799
[4]
Pathophysiology and Treatment of Coagulopathy in Massive Hemorrhage and Hemodilution [J].
Bolliger, Daniel ;
Goerlinger, Klaus ;
Tanaka, Kenichi A. .
ANESTHESIOLOGY, 2010, 113 (05) :1205-1219
[5]
The predictive value of modified computerized thromboelastography and platelet function analysis for postoperative blood loss in routine cardiac surgery [J].
Cammerer, U ;
Dietrich, W ;
Rampf, T ;
Braun, SL ;
Richter, JA .
ANESTHESIA AND ANALGESIA, 2003, 96 (01) :51-57
[6]
CLOTTING FACTOR LEVELS AND THE RISK OF DIFFUSE MICROVASCULAR BLEEDING IN THE MASSIVELY TRANSFUSED PATIENT [J].
CIAVARELLA, D ;
REED, RL ;
COUNTS, RB ;
BARON, L ;
PAVLIN, E ;
HEIMBACH, DM ;
CARRICO, CJ .
BRITISH JOURNAL OF HAEMATOLOGY, 1987, 67 (03) :365-368
[7]
Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests [J].
Coakley, Margaret ;
Reddy, Kalpana ;
Mackie, Ian ;
Mallett, Susan .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (04) :548-553
[8]
*DER C SGFTWBCAP, 2009, TRANSFUS MED HEMOTH, V36, P388
[9]
Dzik Walter H, 2004, Curr Hematol Rep, V3, P324
[10]
Enriquez L J, 2009, Br J Anaesth, V103 Suppl 1, pi14, DOI 10.1093/bja/aep318