Boneloc bone-cement - Experience in hip arthroplasty during a 3-year period

被引:23
作者
Abdel-Kader, KFM [1 ]
Allcock, S [1 ]
Walker, DI [1 ]
Chaudhry, SB [1 ]
机构
[1] Rochdale Infirm, Dept Orthopaed Surg, Rochdale OL12 0NB, England
关键词
boneloc; cement; hip arthroplasty; early loosening; cement failure;
D O I
10.1054/arth.2001.25561
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Polymethyl methacrylate (PMMA) bone-cement was introduced in the 1960s for fixation of total hip arthroplasty replacement components. Long-term results of cement fixation for hip and knee arthroplasty have been extremely good. Although the use of PMMA bone-cement has enabled long-term survival of joint arthroplasty implants, there has been concern about aseptic loosening. This concern led to the introduction of Boneloc bone-cement (Biomet, Warsaw, IN) in the early 1990s. It was hoped that with the improved physical and chemical characteristics of Boneloc, there would be less aseptic loosening in the long-term. A clinical trial was conducted to evaluate Boneloc bone-cement in cementing the femoral component of the Bimetric total hip arthroplasty prosthesis in 33 hips in 32 patients. On follow-up, 7 stems (24%) developed definite loosening, and 3 stems (10%) were possibly loose. Of the 7 definite loose stems, 5 (17%) were revised because of increasing pain or progressive loosening. Despite the biologic advantages of Boneloc, this study suggests that the chemicals substituted in Boneloc bone-cement led to an alteration in its mechanical properties. These properties proved to be inferior to conventional PMMA bone-cement. There is possible time-dependent deterioration of mechanical properties leading to early aseptic loosening. The conventional PMMA bone-cement has stood the test of time. Research and experimental studies should continue to improve the mechanical properties of Boneloc before further human trials. Key words: Boneloc, cement, hip arthroplasty, early loosening, cement failure.
引用
收藏
页码:811 / 819
页数:9
相关论文
共 42 条
[1]
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]
A SEVERE ASTHMATIC REACTION TO POLY(METHYL METHACRYLATE) DENTURE BASE RESIN [J].
BASKER, RM ;
HUNTER, AM ;
HIGHET, AS .
BRITISH DENTAL JOURNAL, 1990, 169 (08) :250-251
[3]
BERMAN AT, 1984, CLIN ORTHOP RELAT R, V186, P284
[4]
Long-term comparison of Charnley and Stanmore design total hip replacements [J].
Britton, AR ;
Murray, DW ;
Bulstrode, CJ ;
McPherson, K ;
Denham, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :802-808
[5]
2ND-DEGREE ATRIOVENTRICULAR-BLOCK AFTER METHYL-METHACRYLATE [J].
BROWN, DL ;
PARMLEY, CL .
ANESTHESIOLOGY, 1982, 56 (05) :391-392
[6]
BUCHANAN JF, 1988, MED TOXICOL ADV DRUG, V3, P1
[7]
BULLOUGH PG, 1988, ORTHOP CLIN N AM, V19, P611
[8]
CHAO EYS, 1992, CLIN ORTHOP RELAT R, P91
[9]
ANCHORAGE OF THE FEMORAL HEAD PROSTHESIS TO THE SHAFT OF THE FEMUR [J].
CHARNLEY, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1960, 42 (01) :28-30
[10]
CHARNLEY J, 1965, J Bone Joint Surg Br, V47, P354