Analytical-scale microwave-assisted extraction

被引:42
作者
Eskilsson, CS [1 ]
Björklund, E [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
reviews; microwave-assisted extraction; extraction methods; pharmaceutical analysis; pesticides; phenols; metals; polymers; polynuclear aromatic hydrocarbons; polychlorinated biphenyls;
D O I
10.1016/S0021-9673(00)00921-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microwave-assisted extraction (MAE) is a process of using microwave energy to heat solvents in contact with a sample in order to partition analytes from the sample matrix into the solvent. The ability to rapidly heat the sample solvent mixture is inherent to MAE and the main advantage of this technique. By using closed vessels the extraction can be performed at elevated temperatures accelerating the mass transfer of target compounds from the sample matrix. A typical extraction procedure takes 15-30 min and uses small solvent volumes in the range of 10-30 mi. These volumes are about 10 times smaller than volumes used by conventional extraction techniques. In addition, sample throughput is increased as several samples can be extracted simultaneously. In most cases recoveries of analytes and reproducibility are improved compared to conventional techniques, as shown in several applications. This review gives a brief theoretical background of microwave heating and the basic principles of using microwave energy for extraction. It also attempts to summarize all studies performed on closed-vessel MAE until now. The influences of parameters such as solvent choice, solvent volume, temperature, time and matrix characteristics (including water content) are discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:227 / 250
页数:24
相关论文
共 135 条
[1]   WET ASHING OF SOME BIOLOGICAL SAMPLES IN A MICROWAVE OVEN [J].
ABUSAMRA, A ;
MORRIS, JS ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1475-1477
[2]   Speciation of arsenic in fish tissue using microwave-assisted extraction followed by HPLC-ICP-MS [J].
Ackley, KL ;
B'Hymer, C ;
Sutton, KL ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) :845-850
[3]   Extraction of incurred sulphamethazine in swine tissue by microwave assisted extraction and quantification without clean up by high performance liquid chromatography following derivatization with dimethylaminobenzaldehyde [J].
Akhtar, MH ;
Wong, ML ;
Crooks, SRH ;
Sauve, A .
FOOD ADDITIVES AND CONTAMINANTS, 1998, 15 (05) :542-549
[4]  
Akhtar MH, 1997, SPECTROSC-INT J, V13, P33
[5]   SUPERCRITICAL FLUID EXTRACTION FOR THE RAPID-DETERMINATION OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS IN MUNICIPAL INCINERATOR FLY-ASH [J].
ALEXANDROU, N ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2770-2776
[6]  
[Anonymous], 1997, MICROWAVE ENHANCED C
[7]  
[Anonymous], SPECTROSC INT J
[8]  
*ASTM, 1996, D6010 ASTM
[9]  
*ASTM, 1996, D5765 ASTM
[10]  
*ASTM, 1996, D5258 ASTM