A sensitive, robust high-throughput electrochemiluminescence assay for rat insulin

被引:14
作者
Golla, R [1 ]
Seethala, R [1 ]
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Drug Discovery, Princeton, NJ 08543 USA
关键词
insulin; electrochemiluminescence; Origen Technology; sandwich immunoassay; high-throughput assay;
D O I
10.1177/1087057103260515
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In diabetes research, mouse and rat models are used for in vivo experiments, and quantification of insulin in serum samples under different pathophysiological conditions and after treatment with compounds is essential. There are few commercial radioimmunoassay and enzyme-linked immunosorbent assay (ELISA) assay kits to determine the rat/mouse plasma levels of insulin. However, reliability in insulin measurements using the available biological assays is a great concern. The authors report a robust, extremely sensitive electrochemiluminescence (ECL) insulin assay using the Origen technology platform. The assay performance, as judged by the Z' value of 0.82 +/- 0.03 and the signal-to-background (S/B) ratio of 133, suggests that this is a robust and reliable assay. The intra-assay and interassay variation is less than 5%. The dynamic range of detection for insulin is 5 pg to 5 ng in the ECL assays. Recovery of insulin was about 100% when different volumes of serum were spiked with exogenous insulin. These results suggest that the ECL insulin assay is an extremely sensitive, robust, nonradioactive homogeneous assay and can be used successfully to determine the insulin levels in rodent serum samples.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 12 条
[1]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[2]   ONE-STEP SANDWICH ENZYME-IMMUNOASSAY FOR INSULIN USING MONOCLONAL-ANTIBODIES [J].
BURGI, W ;
BRINER, M ;
FRANKEN, N ;
KESSLER, AC .
CLINICAL BIOCHEMISTRY, 1988, 21 (05) :311-314
[3]  
Chevenne D, 1999, DIABETES METAB, V25, P459
[4]   HOW TO MEASURE PLASMA-INSULIN [J].
CLARK, PMS ;
HALES, CN .
DIABETES-METABOLISM REVIEWS, 1994, 10 (02) :79-90
[5]   A MONOCLONAL-BASED, 2-SITE ENZYME-IMMUNOASSAY OF HUMAN INSULIN [J].
COMITTI, R ;
RACCHETTI, G ;
GNOCCHI, P ;
MORANDI, E ;
GALANTE, YM .
JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 99 (01) :25-37
[6]   A NEW NONISOTOPIC DETECTION SYSTEM FOR IMMUNOASSAYS [J].
DEAVER, DR .
NATURE, 1995, 377 (6551) :758-760
[7]   Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective [J].
Findlay, JWA ;
Smith, WC ;
Lee, JW ;
Nordblom, GD ;
Das, I ;
DeSilva, BS ;
Khan, MN ;
Bowsher, RR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 21 (06) :1249-1273
[8]   Acute glucocorticoid treatment increases urinary biotin excretion and serum biotin [J].
Rathman, SC ;
Lewis, B ;
McMahon, RJ .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2002, 282 (03) :E643-E649
[9]   Report of the American Diabetes Association's task force on standardization of the insulin assay [J].
Robbins, DC ;
Andersen, L ;
Bowsher, R ;
Chance, R ;
Dinesen, B ;
Frank, B ;
Gingerich, R ;
Goldstein, D ;
Widemeyer, HM ;
Haffner, S ;
Hales, CN ;
Jarett, L ;
Polonsky, K ;
Porte, D ;
Skyler, J ;
Webb, G ;
Gallagher, K .
DIABETES, 1996, 45 (02) :242-256
[10]   EVALUATION OF A SOLID-PHASE MONOCLONAL ANTIBODY-BASED ENZYME-IMMUNOASSAY FOR INSULIN IN HUMAN-SERUM [J].
STORCH, MJ ;
ALEXOPOULOS, A ;
KERP, L .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 119 (01) :53-57