Coronary artery stenting in unstable angina pectoris: a comparison with stable angina pectoris

被引:11
作者
Clarkson, PBM [1 ]
Halim, M [1 ]
Ray, KK [1 ]
Doshi, S [1 ]
Been, M [1 ]
Singh, H [1 ]
Shiu, MF [1 ]
机构
[1] Walsgrave Gen Hosp, Dept Cardiol, Coventry CV2, W Midlands, England
关键词
angina pectoris; stents;
D O I
10.1136/hrt.81.4.393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To compare early complication rates in unselected cases of coronary artery stenting in patients with stable v unstable angina. Setting-Tertiary referral centre. Patients-390 patients with stable angina pectoris (SAP) and 306 with unstable angina (UAP). Patients treated for acute myocardial infarction (primary angioplasty) or cardiogenic shock were excluded. Interventions-268 coronary stents were attempted in 211 patients (30.3%). Stents used included AVE (63%), Freedom (14%), NIR (7%), Palmaz-Schatz (5%), JO (5%), and Multilink (4%). Intravascular ultrasound was not used in any of the cases. All stented patients were treated with ticlopidine and aspirin together with periprocedural unfractionated heparin. Results-123 stents were successfully deployed in 99 SAP patients v 132 stents in 103 UAP patients. Failed deployment occurred with nine stents in SAP patients, v four in UAP patients (NS). Stent thrombosis occurred in four SAP patients and 11 UAP patients. Multivariate analysis showed no relation between stent thrombosis and clinical presentation (SAP v UAP), age, sex, target vessel, stent length, or make of stent. Stent thrombosis was associated with small vessel size (p < 0.001) and bailout stenting (p = 0.01) compared with elective stenting and stenting for suboptimal PTCA, with strong trends toward smaller stent diameter (p = 0.052) and number of stents deployed (p = 0.06). Most stent thromboses occurred in vessels < 3 mm diameter. Conclusions-Coronary artery stenting in unstable angina is safe in vessels greater than or equal to 3 mm diameter, with comparable initial success and stent thrombosis rates to stenting in stable angina.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 30 条
  • [1] MORPHOLOGY AFTER TRANS-LUMINAL ANGIOPLASTY IN HUMAN-BEINGS
    BLOCK, PC
    MYLER, RK
    STERTZER, S
    FALLON, JT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (07) : 382 - 385
  • [2] CAPUTO RP, 1995, J AM COLL CARDIOL, V25, pA49
  • [3] A NOVEL STRATEGY FOR STENT DEPLOYMENT IN THE TREATMENT OF ACUTE OR THREATENED CLOSURE COMPLICATING BALLOON CORONARY ANGIOPLASTY - USE OF SHORT OR STANDARD (OR BOTH) SINGLE OR MULTIPLE PALMAZ-SCHATZ STENTS
    COLOMBO, A
    GOLDBERG, SL
    ALMAGOR, Y
    MAIELLO, L
    FINCI, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) : 1887 - 1891
  • [4] PREVALENCE OF TOTAL CORONARY-OCCLUSION DURING THE EARLY HOURS OF TRANSMURAL MYOCARDIAL-INFARCTION
    DEWOOD, MA
    SPORES, J
    NOTSKE, R
    MOUSER, LT
    BURROUGHS, R
    GOLDEN, MS
    LANG, HT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1980, 303 (16) : 897 - 902
  • [5] EECKHOUT E, 1995, J INVASIVE CARDIOL, V7, pA7
  • [6] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [7] THROMBOSIS AND RESTENOSIS AFTER STENTING IN FAILED ANGIOPLASTY - COMPARISON WITH ELECTIVE STENTING
    FOLEY, JB
    BROWN, RIG
    PENN, IM
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (01) : 12 - 20
  • [8] MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES
    GEORGE, BS
    VOORHEES, WD
    ROUBIN, GS
    FEARNOT, NE
    PINKERTON, CA
    RAIZNER, AE
    KING, SB
    HOLMES, DR
    TOPOL, EJ
    KEREIAKES, DJ
    HARTZLER, GO
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) : 135 - 143
  • [9] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [10] RESULTS OF INTRACORONARY STENTS FOR MANAGEMENT OF CORONARY DISSECTION AFTER BALLOON ANGIOPLASTY
    HAUDE, M
    ERBEL, R
    STRAUB, U
    DIETZ, U
    SCHATZ, R
    MEYER, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08) : 691 - 696