Biomechanical analysis of the osseointegration of porous tantalum implants

被引:38
作者
Fraser, David [1 ]
Funkenbusch, Paul [2 ]
Ercoli, Carlo [1 ]
Meirelles, Luiz [1 ]
机构
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodontol, Rochester, NY 14620 USA
[2] Univ Rochester, Dept Mech Engn, Rochester, NY 14620 USA
关键词
TITANIUM IMPLANT; DENTAL IMPLANTS; RESONANCE FREQUENCY; BONE-FORMATION; INTERFACE; STABILITY; ANISOTROPY; INGROWTH;
D O I
10.1016/j.prosdent.2019.09.014
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Statement of problem. Although implants containing porous tantalum undergo osseointegration, whether this material significantly alters new bone formation and improves implant stability during healing in comparison to titanium is unclear. Purpose. The purpose of this in vivo study was to determine the influence of the inclusion of porous tantalum into a dental implant on the biomechanical properties of the bone-implant interface and peri-implant bone which may contribute to secondary implant stability. Material and methods. Threaded titanium implants with a porous tantalum midsection (Trabecular Metal Dental Implant; Zimmer Biomet) or without (Tapered Screw-Vent; Zimmer Biomet) were placed in rabbit tibiae and allowed to heal for 4, 8, or 12 weeks. The implants were evaluated by resonance frequency analysis and removed with surrounding bone for nanoindentation testing. Two-way ANOVA was used to determine the impact of implant type, bone region, and time on the outcomes implant stability quotient (ISQ), hardness, and elastic modulus (alpha=.05). Results. Resonance frequency analysis found no significant difference in ISQ values between implant types at 4, 8, or 12 weeks, and ISQ values did not increase for either implant over time. Nanoindentation showed no significant differences in hardness or elastic modulus in newly formed bone adjacent to either implant type at any time point. Conclusions. The stiffness of the bone-implant interface was similar for threaded titanium implants with or without porous tantalum when placed in the rabbit tibia and allowed to heal for at least 4 weeks. The new peri-implant bone adjacent to dental implants containing porous tantalum showed no difference in nanomechanical properties to the new bone around implants comprised completely of threaded titanium at all healing time points.
引用
收藏
页码:811 / 820
页数:10
相关论文
共 31 条
[1]
OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]
Development and Applications of Porous Tantalum Trabecular Metal-Enhanced Titanium Dental Implants [J].
Bencharit, Sompop ;
Byrd, Warren C. ;
Altarawneh, Sandra ;
Hosseini, Bashir ;
Leong, Austin ;
Reside, Glenn ;
Morelli, Thiago ;
Offenbacher, Steven .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (06) :817-826
[3]
De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[4]
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[5]
IMPLANT FIXATION IMPROVED BY CLOSE FIT - CYLINDRICAL IMPLANT - BONE INTERFACE STUDIED IN RABBITS [J].
CARLSSON, L ;
ROSTLUND, T ;
ALBREKTSSON, B ;
ALBREKTSSON, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (03) :272-275
[6]
Clinical Significance of the Use of Resonance Frequency Analysis in Assessing Implant Stability: A Systematic Review [J].
Chen, Maggie Hsiao-Mei ;
Lyons, Karl M. ;
Tawse-Smith, Andrew ;
Ma, Sunyoung .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) :51-+
[7]
Retrospective analysis of porous tantalum trabecular metal-enhanced titanium dental implants [J].
Edelmann, Alexander R. ;
Patel, Devang ;
Allen, Riley K. ;
Gibson, Chad J. ;
Best, Al M. ;
Bencharit, Sompop .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) :404-410
[8]
Bone response to porous tantalum implants in a gap-healing model [J].
Fraser, David ;
Mendonca, Gustavo ;
Sartori, Elisa ;
Funkenbusch, Paul ;
Ercoli, Carlo ;
Meirelles, Luiz .
CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (02) :156-168
[9]
Insights into reference point indentation involving human cortical bone: Sensitivity to tissue anisotropy and mechanical behavior [J].
Granke, Mathilde ;
Coulmier, Aurelie ;
Uppuganti, Sasidhar ;
Gaddy, Jennifer A. ;
Does, Mark D. ;
Nyman, Jeffry S. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 37 :174-185
[10]
Effects of Biomechanical Properties of the Bone-Implant Interface on Dental Implant Stability: From In Silico Approaches to the Patient's Mouth [J].
Haiat, Guillaume ;
Wang, Hom-Lay ;
Brunski, John .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 16, 2014, 16 :187-213