Measurement of colonic polyps by radiologists and endoscopists: Who is most accurate?

被引:17
作者
Punwani, S. [1 ]
Halligan, S. [1 ]
Irving, P. [2 ]
Bloom, S. [2 ]
Bungay, A. [2 ]
Greenhalgh, R. [1 ]
Godbold, J. [1 ]
Taylor, S. A. [1 ]
Altman, D. G. [3 ]
机构
[1] UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
[2] UCL Hosp, Dept Gastroenterol, London, England
[3] Wolfson Coll Annexe, Ctr Stat Med, Oxford, England
关键词
colon; CT; CT colonography; cancer; colonoscopy; measurment;
D O I
10.1007/s00330-007-0830-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose was to determine the accuracy of polyp measurement by endoscopy and CT. A colonic phantom was constructed containing 12 simulated polyps of known diameter. Polyp diameter was estimated during endoscopy by two observers independently. The phantom was then scanned using a 64-detector-row machine and diameter estimated by a further two observers independently, using 2D and 3D visualisation methods. All measurements were obtained twice. Bland-Altman statistics were used to assess agreement between observers' estimates and the reference diameter. The mean difference between observers' measurements and the reference diameter was smallest for estimates made using 3D CT (-0.09 mm and -0.03 mm) and greatest for endoscopy (-1.10 mm and -1.19 mm), with 2D CT intermediate. However, 95% limits of agreement were largest for 3D CT estimates (-4.38 mm to 4.20 mm). Estimates by 2D CT consistently overestimated polyp diameter, whereas endoscopy consistently underestimated diameter. In contrast, measurements by 3D CT were a combination of over- and under-estimates, with a tendency for disagreement to increase with the size of the polyp. The effect of observer experience was small and repeatability was best for 2D CT. Measurement error was encountered with all three modalities tested. Estimates made by 2D CT were believed to offer the best compromise overall.
引用
收藏
页码:874 / 881
页数:8
相关论文
共 21 条
[1]
A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
CT colonography:: automatic measurement of polyp diameter compared with manual assessment -: an in-vivo study [J].
Burling, D. ;
Halligan, S. ;
Taylor, S. A. ;
Honeyfield, L. ;
Roddie, M. E. .
CLINICAL RADIOLOGY, 2007, 62 (02) :145-151
[4]
Polyp measurement using CT colonography: Agreement with colonoscopy and effect of viewing conditions on interobserver and intraobserver agreement [J].
Burling, David ;
Halligan, Steve ;
Taylor, Stuart ;
Brennand, Duncan J. ;
Altman, Douglas G. ;
Bassett, Paul ;
Atkin, Wendy ;
Bartram, Clive I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :1597-1604
[5]
PRELIMINARY EVALUATION OF THE PROTOTYPE STEREOSCOPIC ENDOSCOPE - PRECISE 3-DIMENSIONAL MEASUREMENT SYSTEM [J].
CATALANO, MF ;
VANDAM, J ;
BEDFORD, R ;
COTHREN, RM ;
SIVAK, MV .
GASTROINTESTINAL ENDOSCOPY, 1993, 39 (01) :23-28
[6]
FENNERTY MB, 1993, AM J GASTROENTEROL, V88, P496
[7]
Is in vivo measurement of size of polyps during colonoscopy accurate? [J].
Gopalswamy, N ;
Shenoy, VN ;
Choudhry, U ;
Markert, RJ ;
Peace, N ;
Bhutani, MS ;
Barde, CJ .
GASTROINTESTINAL ENDOSCOPY, 1997, 46 (06) :497-502
[8]
CT colonography: Results and limitations [J].
Halligan, Steve ;
Taylor, Stuart A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (03) :400-408
[9]
HOW ACCURATE ARE ENDOSCOPIC ESTIMATES OF SIZE [J].
MARGULIES, C ;
KREVSKY, B ;
CATALANO, MF .
GASTROINTESTINAL ENDOSCOPY, 1994, 40 (02) :174-177
[10]
Morales TG, 1996, GASTROINTEST ENDOSC, V43, P25