An experience of Health Technology Assessment in new models of care for subjects with Parkinson's disease by means of a new wearable device

被引:19
作者
Giansanti, Daniele [1 ]
Maccioni, Giovanni [1 ]
Morelli, Sandra [1 ]
机构
[1] Italian Natl Inst Hlth, Technol & Hlth Dept, Rome, Italy
来源
TELEMEDICINE JOURNAL AND E-HEALTH | 2008年 / 14卷 / 05期
关键词
parkinson' disease; GEMU; step counting; Health Technology Assessment;
D O I
10.1089/tmj.2007.0078
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Step counting is an important index of motion activity and it is currently used in the management of obesity, in applications for the prevention of cardiovascular problems, in diabetes care, and in motion rehabilitation. Commercial pedometers are not appropriate for telemonitoring subjects with motion disability such as Parkinson's disease. The aim of this paper was to test the integration of a Gastrocnemius Expansion Measurement Unit (GEMU) for step counting in a telemedicine application involving subjects with Parkinson's Disease. The test of GEMU in a new model of care was performed on 6 subjects with Parkinson's disease at Level 3 of the Tinetti test of unbalance. They were asked to record binary information about the correct assumption of dopaminergic therapy. Results showed greater than 97% success of monitoring. A statistical analysis also shows (p < 0.05) the feasibility of correlating the decrement of mobility in terms of the step counting with an incorrect assumption of dopaminergic therapy. Furthermore, the methodology showed a high degree of acceptance, and the users gave suggestions for future improvements, especially related to the interface between GEMU and home care itself.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 14 条
[1]   A CLINICAL DISABILITY RATING FOR PARKINSON PATIENTS [J].
ALBA, A ;
TRAINOR, FS ;
RITTER, W ;
DACSO, MM .
JOURNAL OF CHRONIC DISEASES, 1968, 21 (07) :507-&
[2]   Using activity monitors to measure physical activity in free-living conditions [J].
Berlin, Jaime E. ;
Storti, Kristi L. ;
Brach, Jennifer S. .
PHYSICAL THERAPY, 2006, 86 (08) :1137-1145
[3]   ACCURACY OF SELF-REPORTED DISABILITY IN PATIENTS WITH PARKINSONISM [J].
BROWN, RG ;
MACCARTHY, B ;
JAHANSHAHI, M ;
MARSDEN, CD .
ARCHIVES OF NEUROLOGY, 1989, 46 (09) :955-959
[4]   Walking behaviour and glycemic control in type 2 diabetes: Seasonal and gender differences-study design and methods [J].
Dasgupta, Kaberi ;
Chan, Cathy ;
Da Costa, Deborah ;
Pilote, Louise ;
De Civita, Mirella ;
Ross, Nancy ;
Strachan, Ian ;
Sigal, Ronald ;
Joseph, Lawrence .
CARDIOVASCULAR DIABETOLOGY, 2007, 6 (1)
[5]  
EISENMANN JC, 2007, INT J OBES LOND 0130
[6]  
Fahn S., 1987, RECENT DEV PARKINSON, V2
[7]   Telemonitoring and telerehabilitation of patients with Parkinson's disease: Health technology assessment of a novel wearable step counter [J].
Giansanti, Daniele ;
Macellari, Velio ;
Maccioni, Giovanni .
TELEMEDICINE JOURNAL AND E-HEALTH, 2008, 14 (01) :76-83
[8]  
IBRIGHT C, 2006, J WOMENS HLTH LARCHM, V15, P271
[9]  
Kandel E.R, 2000, PRINCIPI NEUROSCIENZ
[10]  
Keenan D. Barry, 2005, V41, P329