A new HPLC micromethod to measure total plasma homocysteine in newborn

被引:9
作者
Bartesaghi, S [1 ]
Accinni, R
De Leo, G
Cursano, CF
Campolo, J
Galluzzo, C
Vegezzi, PG
Parodi, O
机构
[1] Sacra Famiglia FBF AfaR, Erba, CO, Italy
[2] Niguarda Hosp, CNR, Inst Clin Physiol, Sect Milan, Milan, Italy
关键词
total plasma homocysteine; newborn; high-performance liquid chromatography;
D O I
10.1016/S0731-7085(00)00573-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Total plasma homocysteine (tHcy) in children may be an useful biochemical marker for genetic risk of premature cardiovascular disease. We reported a rapid, isocratic HPLC method able to process very small amount of newborn plasma samples. A blood sample from heel capillary circulation was collected, using a heparinized capillary glass tube. Plasma sample from 1 to 10 mul was derivatized with ammonium-7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate after reduction with tri-n-butylphosphine and analyzed on Discovery C18 column, with a solution of acetonitrile-dihydrogenphosphate 0.1 M (8:92 v/v pH*2.1). This assay ensures a good recovery (95%), precision (CV 4.5%) and linearity (y = 2.41x + 0.31, r = 1). Due to its simplicity and reliability, our method is suitable for routine analysis of tHcy and other aminothiols (Cys, Cys-Gly, GSH) assessed for clinical and research purposes. With this HPLC method we have assayed tHcy levels in 1400 apparently healthy newborn babies (tHcy mean value = 4.9 +/- 2.7 muM). In conclusion, this accurate and linear HPLC method allows measurement of tHcy in newborn during the routinary capillary blood collection in the fourth living day without any other invasive procedure. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1137 / 1141
页数:5
相关论文
共 14 条
[1]   High-performance liquid chromatographic determination of total plasma homocysteine with or without internal standards [J].
Accinni, R ;
Campolo, J ;
Bartesaghi, S ;
De Leo, G ;
Lucarelli, C ;
Cursano, CF ;
Parodi, O .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :397-400
[2]   Hyperhomocysteinemia induced by folic acid deficiency and methionine load - Applications of a modified HPLC method [J].
Durand, P ;
Fortin, LJ ;
LussierCacan, S ;
Davignon, J ;
Blache, D .
CLINICA CHIMICA ACTA, 1996, 252 (01) :83-93
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD WITH FLUORESCENCE DETECTION FOR THE DETERMINATION OF TOTAL HOMOCYST(E)INE IN PLASMA [J].
FERMO, I ;
ARCELLONI, C ;
DEVECCHI, E ;
VIGANO, S ;
PARONI, R .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :171-176
[4]   FLUOROGENIC REAGENTS, HAVING BENZOFURAZAN STRUCTURE, IN LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
UZU, S ;
TOYOOKA, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (12) :1395-1403
[5]   DETERMINATION OF PLASMA HOMOCYSTEINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
JACOBSEN, DW ;
GATAUTIS, VJ ;
GREEN, R .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (01) :208-214
[6]  
JACOBSEN DW, 1994, CLIN CHEM, V40, P873
[7]  
Kuo K, 1997, CLIN CHEM, V43, P1653
[8]  
MANSOOR MA, 1992, ANAL BIOCHEM, V200, P218, DOI 10.1016/0003-2697(92)90456-H
[9]  
Reddy MN, 1997, CLIN CHIM ACTA, V262, P153
[10]  
REFSUM H, 1989, CLIN CHEM, V35, P1921