Reproducibility of measurements of cerebral infarct volume on CT scans

被引:87
作者
van der Worp, HB
Claus, SP
Bär, PR
Ramos, LMP
Algra, A
van Gijn, J
Kappelle, LJ
机构
[1] Univ Utrecht, Med Ctr, Dept Neurol, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[3] Univ Utrecht, Med Ctr, Julius Ctr Patient Oriented Res, NL-3508 GA Utrecht, Netherlands
关键词
cerebral infarction; computer-assisted image processing; stroke assessment; tomography; X-ray computed;
D O I
10.1161/01.STR.32.2.424
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Infarct volume is increasingly used as an outcome measure in clinical trials of therapies for acute ischemic stroke. We tested which of 5 different methods to measure infarct size or volume on CT scans has the highest reproducibility. Methods-Infarct volume and total intracranial volume were measured with Leica Q500 MCP image analysis software, or with a caliper, on 38 CT scans of patients who participated in the Tirilazad Efficacy Stroke Study II (TESS II). The scans were performed 8 days (+/-2 days) after the onset of symptoms. The 5 methods tested were based on (1) semiautomated pixel thresholding, (2) manual tracing of the perimeter, (3) a stereological counting grid, (3) measurement of the 3 largest diameters, and (5) the single largest diameter. The measurements were performed independently by 3, observers; the first observer performed all measurements twice. Results-The single largest diameter did not correlate well with infarct volume. Of the other methods, manual tracing of the perimeter of the infarct had the lowest intraobserver and interobserver variability: coefficients of variation were 8.6% and 14.1%, respectively. For total intracranial volume, manual tracing also provided the highest reproducibility: intraobserver and interobserver coefficients of variation were 3.3% and 4.9%, respectively. Conclusions-Manual tracing of the perimeter is the most reproducible method for measuring the volumes of the infarct and the total intracranial space in multicenter trials of therapies for acute ischemic stroke.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 22 条
[1]   Magnetic resonance imaging of acute stroke [J].
Baird, AE ;
Warach, S .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (06) :583-609
[2]   Enlargement of human cerebral ischemic lesion volumes measured by diffusion-weighted magnetic resonance imaging [J].
Baird, AE ;
Benfield, A ;
Schlaug, G ;
Siewert, B ;
Lovblad, KO ;
Edelman, RR ;
Warach, S .
ANNALS OF NEUROLOGY, 1997, 41 (05) :581-589
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   MEASUREMENTS OF ACUTE CEREBRAL INFARCTION - LESION SIZE BY COMPUTED-TOMOGRAPHY [J].
BROTT, T ;
MARLER, JR ;
OLINGER, CP ;
ADAMS, HP ;
TOMSICK, T ;
BARSAN, WG ;
BILLER, J ;
EBERLE, R ;
HERTZBERG, V ;
WALKER, M .
STROKE, 1989, 20 (07) :871-875
[5]   Timing for fever-related brain damage in acute ischemic stroke [J].
Castillo, J ;
Dávalos, A ;
Marrugat, J ;
Noya, M .
STROKE, 1998, 29 (12) :2455-2460
[6]   The rtPA (Alteplase) 0-to 6-hour acute stroke trial, part A (A0276g) - Results of a double-blind, placebo-controlled, multicenter study [J].
Clark, WM ;
Albers, GW ;
Madden, KP ;
Hamilton, S .
STROKE, 2000, 31 (04) :811-816
[7]   COMPUTER-ASSISTED CATEGORIZATION OF BRAIN COMPUTERIZED-TOMOGRAPHY PIXELS INTO CEREBROSPINAL-FLUID, WHITE MATTER, AND GRAY-MATTER [J].
DELEO, JM ;
SCHWARTZ, M ;
CREASEY, H ;
CUTLER, N ;
RAPOPORT, SI .
COMPUTERS AND BIOMEDICAL RESEARCH, 1985, 18 (01) :79-88
[8]   SOME NEW, SIMPLE AND EFFICIENT STEREOLOGICAL METHODS AND THEIR USE IN PATHOLOGICAL RESEARCH AND DIAGNOSIS - REVIEW ARTICLE [J].
GUNDERSEN, HJG ;
BENDTSEN, TF ;
KORBO, L ;
MARCUSSEN, N ;
MOLLER, A ;
NIELSEN, K ;
NYENGAARD, JR ;
PAKKENBERG, B ;
SORENSEN, FB ;
VESTERBY, A ;
WEST, MJ .
APMIS, 1988, 96 (05) :379-394
[9]  
HUBBARD BM, 1983, LANCET, V1, P1447
[10]   The ABCs of measuring intracerebral hemorrhage volumes [J].
Kothari, U ;
Brott, T ;
Broderick, JP ;
Barsan, WG ;
Sauerbeck, LR ;
Zuccarello, M ;
Khoury, J .
STROKE, 1996, 27 (08) :1304-1305