Analysis of nickel-titanium versus stainless steel instrumentation by means of direct digital imaging

被引:12
作者
Coleman, CL
Svec, TA
Rieger, MR
Suchina, JA
Wang, MM
Glickman, GN
机构
[1] UNIV TEXAS, HLTH SCI CTR, DENT BRANCH, SECT ORAL BIOMAT, HOUSTON, TX 77030 USA
[2] UNIV MICHIGAN, SCH DENT, DEPT CARIOL RESTORAT SCI & ENDODONT, ANN ARBOR, MI USA
关键词
D O I
10.1016/S0099-2399(96)80030-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared step-back preparations in curved canals using nickel-titanium (Ni-Ti) K-files and stainless steel K-files. Forty canals in mesial roots of mandibular molars were embedded in casting resin and cross-sectioned at three levels: 1 to 2 mm from the apical foramen, middle of the curve, and coronal. Direct digital computer images were recorded before and after instrumentation. Superimposition of the images combined with digital subtraction computer software allowed direct measurement of area instrumented, distance of transportation, and shape analysis. The computer software calculated absolute center of gravity for each image analyzed to get a full 360-degree interpretation of the canal transport. Time of instrumentation was recorded. Results showed Ni-Ti files to cause significantly less transportation and remain more centered at the apical level (p < 0.05). Area removed by Ni-Ti and stainless steel files was not significantly different (p < 0.05). Time of instrumentation was not significantly different for Ni-Ti and stainless steel instruments (p < 0.05). Cross-sectional shape of the instrumented canal was not significantly different (p < 0.05).
引用
收藏
页码:603 / 607
页数:5
相关论文
共 16 条
[1]   SHAPING OF SIMULATED ROOT CANALS IN RESIN BLOCKS USING THE STEP-BACK TECHNIQUE WITH K-FILES MANIPULATED IN A SIMPLE IN OUT FILING MOTION [J].
ALODEH, MHA ;
DOLLER, R ;
DUMMER, PMH .
INTERNATIONAL ENDODONTIC JOURNAL, 1989, 22 (03) :107-117
[2]  
ANDREASEN GF, 1978, AM J ORTHOD DENTOFAC, V73, P141, DOI 10.1016/0002-9416(78)90184-7
[3]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[4]   THE INFLUENCE OF DIFFERENT ROOT-CANAL INSTRUMENTS ON ROOT-CANAL PREPARATION - AN INVITRO STUDY [J].
BRISENO, BM ;
SONNABEND, E .
INTERNATIONAL ENDODONTIC JOURNAL, 1991, 24 (01) :15-23
[5]   THE EFFECTS OF 4 INSTRUMENTATION TECHNIQUES ON ROOT-CANAL SHAPE [J].
CALHOUN, G ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1988, 14 (06) :273-277
[6]   COMPARISON OF MECHANICAL AND STANDARD HAND INSTRUMENTATION TECHNIQUES IN CURVED ROOT CANALS [J].
CAMPOS, JM ;
DELRIO, C .
JOURNAL OF ENDODONTICS, 1990, 16 (05) :230-234
[7]   THE EFFECT OF DIFFERENT FILES ON THE PREPARATION SHAPE OF SEVERELY CURVED CANALS [J].
ELDEEB, ME ;
BORAAS, JC .
INTERNATIONAL ENDODONTIC JOURNAL, 1985, 18 (01) :1-7
[8]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[9]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[10]   THE EFFECTS OF CANAL MASTER, FLEX-R, AND K-FLEX INSTRUMENTATION ON ROOT-CANAL CONFIGURATION [J].
LESEBERG, DA ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1991, 17 (02) :59-65