Characterization of metallothionein isoforms by reversed-phase high-performance liquid chromatography with on-line post-column acidification and electrospray mass spectrometric detection

被引:45
作者
Chassaigne, H [1 ]
Lobinski, R [1 ]
机构
[1] CNRS EP132, Lab Chim Bioinorgan & Environm, F-64000 Pau, France
关键词
metallothioneins; proteins; post-column derivatization;
D O I
10.1016/S0021-9673(98)00806-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Post-column acidification of the chromatographic effluent was developed to eliminate artefacts in investigations of the polymorphism of metallothionein (MT) by microbore reversed-phase HPLC with detection by pneumatically assisted electrospray mass spectrometry. Metallated species (Cd, Zn and mixed Cd-Zn complexes) were decomposed on-line to produce apo metallothioneins of which the molecular masses were determined by MS. Besides the simplification of the mass spectra taken at the apexes of the chromatographic peaks, the method resulted in a 10-fold improvement of the detection limit of metallothionein and allowed a more comprehensive and less ambiguous detection and identification of the iso- and subisoforms, The method was applied to the characterization of rabbit liver metallothioneins: rabbit liver MT (purified by size-exclusion chromatography only) and MT-1 and MT-2 isoform fractions purified additionally by anion-exchange chromatography. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 19 条
[1]   Polymorphism and identification of metallothionein isoforms by reversed-phase HPLC with on-line ion spray mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2536-2543
[2]   Speciation of metal complexes with biomolecules by reversed-phase HPLC with ion-spray and inductively coupled plasma mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :267-273
[3]   PHYSICOCHEMICAL CHARACTERIZATION OF METAL-BINDING PROTEINS USING HPLC-ICP-MS, HPLC-MA-AAS AND ELECTROSPRAY-MS [J].
HIGH, KA ;
METHVEN, BA ;
MCLAREN, JW ;
SIU, KWM ;
WANG, J ;
KLAVERKAMP, JF ;
BLAIS, JS .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :393-402
[4]  
HUNZIKER PE, 1991, METHOD ENZYMOL, V205, P421
[5]  
HUNZIKER PE, 1991, METHOD ENZYMOL, V205, P451
[6]  
*IUPAC IUB COMM BI, 1977, J BIOL CHEM, V252, P5939
[7]  
KAGI JHR, 1993, ADV LIF SCI, P29
[8]   CHARACTERIZATION OF ISOPROTEIN PATTERNS IN TISSUE-EXTRACTS AND ISOLATED SAMPLES OF METALLOTHIONEINS BY REVERSE-PHASE HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
KLAUSER, S ;
KAGI, JHR ;
WILSON, KJ .
BIOCHEMICAL JOURNAL, 1983, 209 (01) :71-80
[9]  
LeBlanc JCY, 1997, J ANAL ATOM SPECTROM, V12, P525
[10]   Analysis for metallothioneins using coupled techniques [J].
Lobinski, R ;
Chassaigne, H ;
Szpunar, J .
TALANTA, 1998, 46 (02) :271-289