Study of the catalytic effect of copper(II)-protein complexes on luminol-H2O2 chemiluminescence reaction and its analytical application

被引:27
作者
Li, ZP [1 ]
Li, KA [1 ]
Tong, SY [1 ]
机构
[1] Beijing Univ, Dept Chem, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
protein; copper(II); complex; chemiluminescence; luminol; peroxide;
D O I
10.1080/00032719908542864
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Through flow injection analysis experiments, it was discovered that unsaturated complexes of Cu(ll) with proteins had a much stronger catalytic effect on the luminol-H2O2 chemiluminescence reaction than did Cu(II). Based on this, a new rapid and sensitive method for determination of some proteins in the range 0.1-20.0 mu g ml(-1) was established. The detection limits were at the 0.03-0.05 mu g ml(-1) level for bovine serum albumin (BSA), human serum albumin (HSA), human gamma-globulin (gamma-G), and egg albumin (EA). The method was used for the determination of proteins in human serum with satisfactory results.
引用
收藏
页码:901 / 913
页数:13
相关论文
共 17 条
[1]   FLUOROMETRIC ASSAY OF PROTEINS IN NANOGRAM RANGE [J].
BOHLEN, P ;
STEIN, S ;
DAIRMAN, W ;
UDENFRIEND, S .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1973, 155 (01) :213-220
[2]  
BOSTICK DT, 1975, ANAL CHEM, V47, P7
[3]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[4]   FLOW-INJECTION ANALYSIS FOR MONITORING CHEMI-LUMINESCENT REACTIONS [J].
BURGUERA, JL ;
TOWNSHEND, A ;
GREENFIELD, S .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :209-214
[5]  
DOUMAS BT, 1981, CLIN CHEM, V27, P1642
[6]   DETERMINATION OF A SMALL AMOUNT OF A BIOLOGICAL CONSTITUENT BY THE USE OF CHEMI-LUMINESCENCE .2. DETERMINATION OF ALBUMIN AS A MODEL PROTEIN BY MEANS OF THE FLOW-INJECTION ANALYSIS USING A COBALT(III) COMPLEX COMPOUND AS A CATALYST [J].
HARA, T ;
TORIYAMA, M ;
TSUKAGOSHI, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1984, 57 (01) :289-290
[7]   DETERMINATION OF A SMALL AMOUNT OF BIOLOGICAL CONSTITUENT BY USE OF CHEMI-LUMINESCENCE .3. THE FLOW-INJECTION ANALYSIS OF PROTEIN BY DIRECT INJECTION [J].
HARA, T ;
TORIYAMA, M ;
TSUKAGOSHI, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1984, 57 (06) :1551-1555
[8]   DETERMINATION OF A SMALL AMOUNT OF BIOLOGICAL CONSTITUENT BY USE OF CHEMI-LUMINESCENCE .1. THE FLOW-INJECTION ANALYSIS OF PROTEIN [J].
HARA, T ;
TORIYAMA, M ;
TSUKAGOSHI, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1983, 56 (05) :1382-1387
[9]   THE DETERMINATION OF A SMALL AMOUNT OF BIOLOGICAL CONSTITUENT BY THE USE OF CHEMI-LUMINESCENCE .4. A HIGHLY SENSITIVE DETECTOR FOR THE HPLC OF PROTEIN [J].
HARA, T ;
TORIYAMA, M ;
EBUCHI, T .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1985, 58 (01) :109-114
[10]   Fluorometric determination for micro amounts of albumin and globulin fractions without separation by using alpha,beta,gamma,delta-tetra(4'-carboxyphenyl)porphin [J].
Li, N ;
Li, KA ;
Tong, SY .
ANALYTICAL BIOCHEMISTRY, 1996, 233 (02) :151-155