Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?

被引:132
作者
Hans, D
Srivastav, SK
Singal, C
Barkmann, R
Njeh, CF
Kantorovich, E
Glüer, CC
Genant, HK
机构
[1] Univ Calif San Francisco, Osteoporosis & Arthrit Res Grp, San Francisco, CA 94143 USA
[2] Sunlight Ultrasound Technol Ltd, Rehovot, Israel
[3] Univ Kiel, Dept Diagnost Radiol, Osteoporosediagnost Kiel, D-24098 Kiel, Germany
关键词
D O I
10.1359/jbmr.1999.14.4.644
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, including the spinous processes. in this study, we examined the ability of speed of sound measured at the calcaneus, distal third and ultradistal radius! proximal third phalanx, metacarpal, capitate, patella, and the posterior process of the thoracic spine to differentiate subjects with hip fractures from normal controls. Seventy-nine postmenopausal Caucasian Israeli women who had sustained an atraumatic fracture of the proximal femur within the last 6 months were recruited from the local population (mean age 80 +/- 8.9 years). As controls, 295 postmenopausal Caucasian Israeli women without osteoporotic fractures were also included (mean age 70 +/- 8.7 years). Discrimination Of hip fractures with QUS at all ultrasound sites tvas highly statistically significant (p < 0.01) (odds ratios [ORs] = 1.4-3.0; area under the ROC curve [AUC] 77-92%), except for the hand metacarpal. Distal radius and calcaneus measurements (ORs = 2.4 and 3.0) were the best discriminators of hip fracture patients from controls. Using a forward selective linear regression model, the discriminator values of combined assessment at two sites were investigated. There was moderate improvement in diagnostic value, but the best combination was the calcaneus with the distal radius, which improved the AUC by 3% and raised both the sensitivity and specificity to 94%. These data demonstrate the encouraging potential of improving discrimination of hip fracture by using multiple-site ultrasonic measurements.
引用
收藏
页码:644 / 651
页数:8
相关论文
共 29 条
  • [1] ANTICH PP, 1993, J BONE MINER RES, V8, P301
  • [2] Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women - A prospective study
    Bauer, DC
    Gluer, CC
    Cauley, JA
    Vogt, TM
    Ensrud, KE
    Genant, HK
    Black, DM
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1997, 157 (06) : 629 - 634
  • [3] Breazeale M. A., 1981, METHODS EXPT PHYSICS, V19, P67, DOI DOI 10.1016/S0076-695X(08)60333-6
  • [4] BONE-DENSITY AT VARIOUS SITES FOR PREDICTION OF HIP-FRACTURES
    CUMMINGS, SR
    BLACK, DM
    NEVITT, MC
    BROWNER, W
    CAULEY, J
    ENSRUD, K
    GENANT, HK
    PALERMO, L
    SCOTT, J
    VOGT, TM
    [J]. LANCET, 1993, 341 (8837) : 72 - 75
  • [5] Duboeuf F, 1996, REV RHUM, V63, P427
  • [6] QUANTITATIVE ULTRASOUND OF THE TIBIA - A NOVEL-APPROACH FOR ASSESSMENT OF BONE STATUS
    FOLDES, AJ
    RIMON, A
    KEINAN, DD
    POPOVTZER, MM
    [J]. BONE, 1995, 17 (04) : 363 - 367
  • [7] Genant HK, 1996, J BONE MINER RES, V11, P707
  • [8] GLUER C, 1997, CHARACTERIZE ABILITY
  • [9] Quantitative ultrasound techniques for the assessment of osteoporosis: Expert agreement on current status
    Gluer, CC
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (08) : 1280 - 1288
  • [10] GLUER CC, 1994, J BONE MINER RES S2, V25, pS40