Analytical performance of a multiplexed, bead-based cytokine detection system in small volume samples

被引:15
作者
Bomert, Martin [1 ]
Koellisch, Gabi [1 ]
Roponen, Marjut [2 ]
Lauener, Roger [3 ,4 ,5 ]
Renz, Harald [1 ]
Pfefferle, Petra I. [1 ]
Al-Fakhri, Nadia [1 ]
机构
[1] Univ Marburg, Inst Lab Med & Pathobiochem, D-35043 Marburg, Germany
[2] Natl Inst Hlth & Welf, Dept Environm Hlth, Kuopio, Finland
[3] Univ Zurich, Childrens Hosp, Zurich, Switzerland
[4] Univ Zurich, Christine Kuhne Ctr Allergy Res & Educ, Zurich, Switzerland
[5] Childrens Allergy & Asthma Hosp, Hochgebirgsklin, Davos, Switzerland
关键词
allergy; analytical performance; cytokine measurement; immunology; multiplex assay system;
D O I
10.1515/CCLM.2011.631
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
100118 [医学信息学]; 100208 [临床检验诊断学];
摘要
Background: Multiplexed cytokine measurement offers many advantages over the conventional enzyme-linked immunosorbent assay (ELISA) format when applied in large-scale epidemiological studies or clinical trials. In the present study we set out to define the reliability and consistency of a suspension multiplexed protein array, the cytometric bead array (CBA), in large-scale, longitudinal studies. Methods: The cytokines interleukin (IL)-5, IL-10, tumor necrosis factor-alpha (TNF-alpha) and interferon-gamma (IFN-gamma) were measured in pediatric samples from childhood asthma and allergy studies. Analytical performance of CBA was determined in sample supernatants and CBA was compared to conventional ELISA. Results: Within-run and total imprecision were between 5.2% -10.8% and 5.6%-13.2%, respectively, at three different concentrations for all cytokines. Slopes of dilution linearity were between 1.01 and 1.31 for the four cytokines. The recovery rate at two different concentrations of the cytokines was between 97% and 113%. Lower limits of detection and quantification as well as functional sensitivity were determined. Comparison of the multiplex array and solid phase method showed good correlation with r between 0.82 and 0.93. The sample volume required for the multiplex format was 25% of the ELISA sample volume. Conclusions: CBA analytical evaluation and comparison to an ELISA format demonstrated high reproducibility, sensitivity and good applicability for small volume samples.
引用
收藏
页码:1691 / 1693
页数:3
相关论文
共 4 条
[1]
Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges [J].
Ellington, Allison A. ;
Kullo, Iftikhar J. ;
Bailey, Kent R. ;
Klee, George G. .
CLINICAL CHEMISTRY, 2010, 56 (02) :186-193
[2]
Cytometric bead array: a multiplexed assay platform with applications in various areas of biology [J].
Morgan, E ;
Varro, R ;
Sepulveda, H ;
Ember, JA ;
Apgar, J ;
Wilson, J ;
Lowe, L ;
Chen, R ;
Shivraj, L ;
Agadir, A ;
Campos, R ;
Ernst, D ;
Gaur, A .
CLINICAL IMMUNOLOGY, 2004, 110 (03) :252-266
[3]
Cord blood cytokines are modulated by maternal farming activities and consumption of farm dairy products during pregnancy: The PASTURE Study [J].
Pfefferle, Petra Ina ;
Buechele, Gisela ;
Bluemer, Nicole ;
Roponen, Marjut ;
Ege, Markus Johannes ;
Krauss-Etschmann, Susanne ;
Genuneit, Jon ;
Hyvaerinen, Anne ;
Hirvonen, Maija-Riitta ;
Lauener, Roger ;
Pekkanen, Juha ;
Riedler, Josef ;
Dalphin, Jean Charles ;
Brunekeef, Bert ;
Braun-Fahrlaender, Charlotte ;
von Mutius, Erika ;
Renz, Harald .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2010, 125 (01) :108-115
[4]
The PASTURE project: EU support for the improvement of knowledge about risk factors and preventive factors for atopy in Europe [J].
von Mutius, E ;
Schmid, S .
ALLERGY, 2006, 61 (04) :407-413