Registration of standardized histological images in feature space

被引:7
作者
Bagci, Ulas [1 ]
Bai, Li [1 ]
机构
[1] Univ Nottingham, Collaborat Med Image Anal Grid, Nottingham NG7 2RD, England
来源
MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3 | 2008年 / 6914卷
关键词
registration; standardization; feature space; edgeness; volume reconstruction; histological images; automatic best reference slice selection;
D O I
10.1117/12.770219
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, we propose three novel and important methods for the registration of histological images for 3D reconstruction. First, possible intensity variations and nonstandardness in images are corrected by an intensity standardization process which maps the image scale into a standard scale where the similar intensities correspond to similar tissues meaning. Second, 2D histological images are mapped into a feature space where continuous variables are used as high confidence image features for accurate registration. Third, we propose an automatic best reference slice selection algorithm that improves reconstruction quality based on both image entropy and mean square error of the registration process. We demonstrate that the choice of reference slice has a significant impact on registration error, standardization, feature space and entropy information. After 2D histological slices are registered through an affine transformation with respect to an automatically chosen reference, the 3D volume is reconstructed by co-registering 2D slices elastically.
引用
收藏
页数:9
相关论文
共 18 条
[1]  
BAGCI U, 2007, CMIAG ANN REPORT
[2]  
BAGGCI U, 2007, 20 BRAZ S COMP GRAPH
[3]  
Butz J.-P., 2001, Medical Image Computing and Computer-Assisted Intervention, P549
[4]   Spatial transformation and registration of brain images using elastically deformable models [J].
Davatzikos, C .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 66 (02) :207-222
[5]  
Ge YL, 2000, J MAGN RESON IMAGING, V12, P715, DOI 10.1002/1522-2586(200011)12:5<715::AID-JMRI8>3.3.CO
[6]  
2-4
[7]  
Gee JC, 1997, LECT NOTES COMPUT SC, V1205, P63, DOI 10.1007/BFb0029225
[8]  
GUEST E, 2001, BIOIMAGING, V3, P154
[9]   3D volume reconstruction of a mouse brain from histological sections using warp filtering [J].
Ju, Tao ;
Warren, Joe ;
Carson, James ;
Bello, Musodiq ;
Kakadiaris, Ioannis ;
Chiu, Wah ;
Thaller, Christina ;
Eichele, Gregor .
JOURNAL OF NEUROSCIENCE METHODS, 2006, 156 (1-2) :84-100
[10]   A survey of hierarchical non-linear medical image registration [J].
Lester, H ;
Arridge, SR .
PATTERN RECOGNITION, 1999, 32 (01) :129-149