Determination of phenols in water using liquid phase microextraction with back extraction combined with high-performance liquid chromatography

被引:125
作者
Zhao, LM [1 ]
Lee, HK [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
liquid phase microextraction with back extraction; extraction methods; water analysis; phenols;
D O I
10.1016/S0021-9673(01)01199-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid phase microextraction with back extraction (LPME/BE) combined with high-performance liquid chromatography (HPLC) was studied for the determination of a variety of phenols in water samples. The target compounds were extracted from 2-ml aqueous sample adjusted to pH 1 (donor solution) through a microliter-size organic solvent phase (400-mul n-hexane), confined inside a small PTFE ring, and finally into a 1-mul basic aqueous acceptor microdrop suspended in the aforementioned solvent phase from the tip of a microsyringe needle. After extracting for a prescribed time, the microdrop was taken back into the syringe and directly injected into an HPLC for detection. Factors relevant to the extraction procedure were studied. At the optimized extraction conditions, a large enrichment factor (more than 100-fold) can be achieved for most of the phenols within 35 min. The detection limit range was 0.5-2.5 mug/l for different analytes in aqueous samples. The results demonstrate the suitability of the LPME/BE approach to the analysis of polar compounds in aqueous samples. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 29 条
[1]   Strategies for solvent selection - A literature review [J].
Barwick, VJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (06) :293-309
[2]   Determination of toxic nitrophenols in the atmosphere by high-performance liquid chromatography [J].
Belloli, R ;
Barletta, B ;
Bolzacchini, E ;
Meinardi, S ;
Orlandi, M ;
Rindone, B .
JOURNAL OF CHROMATOGRAPHY A, 1999, 846 (1-2) :277-281
[3]   SOLID-PHASE MICROEXTRACTION OF NITROGEN-CONTAINING HERBICIDES [J].
BOYDBOLAND, AA ;
PAWLISZYN, JB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :163-172
[4]   DETERMINATION OF PHENOLIC-COMPOUNDS IN SURFACE-WATER USING ONLINE LIQUID-CHROMATOGRAPHIC PRECOLUMN-BASED COLUMN-SWITCHING TECHNIQUES [J].
BROUWER, ER ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (02) :223-231
[5]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[6]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[7]  
BUSTO O, 1991, CHROMATOGRAPHIA, V32, P556
[8]   Analysis of phenolic compounds in effluent by solid-phase extraction and gas chromatography mass spectrometry with direct on-column benzylation: Sensitive negative ion chemical ionisation gas chromatography mass spectrometry detection of phenyl benzyl ethers [J].
Cheung, J ;
Wells, RJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) :203-211
[9]  
*EPA, 1984, 625 EPA, P153
[10]  
*EPA, 1995, 8041 EPA, P1