Interobserver variability in the evaluation of chronic mesenteric ischemia with gadolinium-enhanced MR angiography

被引:30
作者
Carlos, RC
Stanley, JC
Stafford-Johnson, D
Prince, MR
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Robert Wood Johnson Clin Scholars Program, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Surg, Ann Arbor, MI 48109 USA
[4] Cornell Univ, Dept Radiol, New York, NY USA
[5] Univ Dublin, Dept Radiol, Dublin, Ireland
关键词
chronic mesenteric ischemia; gadolinium-enhanced MR angiography; interobserver variability; technology assessment;
D O I
10.1016/S1076-6332(03)80767-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to assess interobserver variability in the interpretation of gadolinium-enhanced magnetic resonance (MR) angiograms of splanchnic vessels in patients suspected of having chronic mesenteric ischemia (CMI). Materials and Methods. Two readers blinded to the initial interpretation retrospectively reviewed gadolinium-enhanced MR angiograms obtained for suspected CMI in 26 patients (20 women and six men; age range, 23-77 years; mean age, 61 years) who also underwent conventional angiography. Each reader graded the degree of stenosis based on the percentage diameter reduction of the celiac artery (CA), superior mesenteric artery (SMA), and inferior mesenteric artery (IMA) by using a five-point ordinal scale: 0, no stenosis; 1, mild stenosis (<50%); 2, moderate stenosis (50%-75%); 3, severe stenosis (>75%); 4, occluded artery. Using the conventional angiogram as a reference standard, authors determined sensitivity and specificity for each observer, assigning two thresholds (grades 2 and 3) as significant stenoses. A kappa statistic (kappa) measured interobserver agreement. Results. With grade 2 stenosis used as a threshold, cumulative accuracies for detecting significant stenosis were 0.95 (95% confidence interval, 0.86-0.99) for reader A and 0.97 (0.88-1.0) for reader B. Interobserver agreement for grading proximal splanchnic stenosis was 0.90 for CA, 0.92 for SMA, and 0.48 for IMA. Conclusion. Gadolinium-enhanced MR angiography is reproducibly accurate for detection of proximal splanchnic artery stenosis, with good to excellent interobserver agreement.
引用
收藏
页码:879 / 887
页数:9
相关论文
共 38 条
[1]  
Baden JG, 1999, JMRI-J MAGN RESON IM, V10, P369, DOI 10.1002/(SICI)1522-2586(199909)10:3<369::AID-JMRI19>3.0.CO
[2]  
2-X
[3]   History of mesenteric ischemia - The evolution of a diagnosis and management [J].
Boley, SJ ;
Brandt, LJ ;
Sammartano, RJ .
SURGICAL CLINICS OF NORTH AMERICA, 1997, 77 (02) :275-+
[4]   Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: New observation of a potential pitfall [J].
Chiowanich, P ;
Mitchell, DG ;
Ortega, HV ;
Mohamed, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) :523-527
[5]   Hepatic MR angiography: A multiobserver comparison of visualization methods [J].
Choyke, PL ;
Yim, P ;
Marcos, H ;
Ho, VB ;
Mullick, R ;
Summers, RM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :465-470
[6]  
Dalman RL, 1996, CIRCULATION, V94, P206
[7]   Diagnosis of renal vascular disease with MR angiography [J].
Dong, Q ;
Schoenberg, SO ;
Carlos, RC ;
Neimatallah, M ;
Cho, KJ ;
Williams, DM ;
Kazanjian, SN ;
Prince, MR .
RADIOGRAPHICS, 1999, 19 (06) :1535-1554
[8]   Complications of peripheral arteriography: A new system to identify patients at increased risk [J].
Egglin, TKP ;
OMoore, PV ;
Feinstien, AR ;
Waltman, AC .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (06) :787-794
[9]  
FERRONE GJ, 1998, ASS U RAD ANN M NEW
[10]  
FLEISS J L, 1990, Critical Reviews in Oral Biology and Medicine, V1, P55