Quartz Crystal Impedance Response of Nonhomogenous Composite Electrodes in Contact with Liquids

被引:27
作者
Daikhin, Leonid [2 ]
Sigalov, Sergey [1 ]
Levi, Mikhael D. [1 ]
Salitra, Gregory [1 ]
Aurbach, Doron [1 ]
机构
[1] Bar Ilan Univ, Dept Chem, IL-52900 Ramat Gan, Israel
[2] Tel Aviv Univ, Raymond & Beverly Sackler Fac Exact Sci, Sch Chem, IL-69978 Ramat Aviv, Israel
关键词
MICROPOROUS CARBONS; IONIC FLUXES; MICROBALANCE; EQCM; FILMS;
D O I
10.1021/ac202410q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new model of quartz-crystal impedance (QCI) of nonuniform layers composed of bumps of carbon particles (either porous or nonporous) and a polymeric binder layer has been proposed. The solid particles are modeled by semispherical and oblate semispheroid bumps embedded into the "sea" of a polymeric binder layer. On the basis of this model and elaborating on the principles of hydrodynamic spectroscopy of composite electrode materials, the geometric and porous structure parameters of nanoporous carbon and nonporous graphite composite electrodes in contact with liquids have been reliably determined. This work is believed to create a solid theoretical background for both advanced studies and optimized formulations of the composite electrodes suited to practical electrochemical devices and for the interpretation of the processes of ions and solvent insertion into nanoporous carbon electrodes uniquely probed by the QCI method (supercapacitive cells, desalination membranes).
引用
收藏
页码:9614 / 9621
页数:8
相关论文
共 31 条
[1]   EXPERIMENTAL ASPECTS OF USE OF THE QUARTZ CRYSTAL MICROBALANCE IN SOLUTION [J].
BRUCKENSTEIN, S ;
SHAY, M .
ELECTROCHIMICA ACTA, 1985, 30 (10) :1295-1300
[2]  
Calvo E., 2009, PIEZOELECTRIC TRANSD, P307, DOI [10.1007/978-3-540-77508-9_13, DOI 10.1007/978-3-540-77508-9_13]
[3]  
Chahar B.S., 2009, WORLD ELECT VEHICLE, V3, P1
[4]   Influence of roughness on the admittance of the quartz crystal microbalance immersed in liquids [J].
Daikhin, L ;
Gileadi, E ;
Katz, G ;
Tsionsky, V ;
Urbakh, M ;
Zagidulin, D .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :554-561
[5]   Effect of surface film structure on the quartz crystal microbalance response in liquids [J].
Daikhin, L ;
Urbakh, M .
LANGMUIR, 1996, 12 (26) :6354-6360
[6]   Hydration forces and liquid-like layer on the ice/metal interface [J].
Daikhin, Leonid ;
Tsionsky, Vladimir .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2007, 19 (37)
[7]  
Dean J. A., 1999, LANGES HDB CHEM, P1118
[8]  
Hatschek E., 1928, VISCOSITY LIQUIDS, P118
[9]   The EQCM: electrogravimetry with a light touch [J].
Hillman, A. Robert .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (7-8) :1647-1660
[10]  
Inzelt G, 2010, ELECTROANALYTICAL METHODS: GUIDE TO EXPERIMENTS AND APPLICATIONS, SECOND EDITION, P257, DOI 10.1007/978-3-642-02915-8_13