Preparation of macromolecular complexes for cryo-electron microscopy

被引:144
作者
Grassucci, Robert A. [1 ]
Taylor, Derek J. [2 ]
Frank, Joachim [1 ,2 ,3 ]
机构
[1] Columbia Univ Coll Phys & Surg, Howard Hughes Med Inst, Dept Biochem & Mol Biophys, New York, NY 10032 USA
[2] Wadsworth Ctr, Albany, NY 12201 USA
[3] Columbia Univ, Dept Biol Sci, New York, NY 10027 USA
关键词
D O I
10.1038/nprot.2007.452
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This protocol describes the preparation of frozen-hydrated single-particle specimens of macromolecular complexes. First, it describes how to create a grid surface coated with holey carbon by first inducing holes in a Formvar film to act as a template for the holey carbon that is stable under cryo-electron microscopy (cryo-EM) conditions and is sample-friendly. The protocol then describes the steps required to deposit the homogeneous sample on the grid and to plunge-freeze the grid into liquid ethane at the temperature of liquid nitrogen, so that it is suitable for cryo-EM visualization. It takes 4-5 h to make several hundred holey carbon grids and about 1 h to make the frozen-hydrated grids. The time required for sample purification varies from hours to days, depending on the sample and the specific procedure required. A companion protocol details how to collect cryo-EM data using an FEI Tecnai transmission electron microscope that can subsequently be processed to obtain a three-dimensional reconstruction of the macromolecular complex.
引用
收藏
页码:3239 / 3246
页数:8
相关论文
共 24 条
[1]   Cryo-negative staining [J].
Adrian, M ;
Dubochet, J ;
Fuller, SD ;
Harris, JR .
MICRON, 1998, 29 (2-3) :145-160
[2]   PREPARATION OF PERFORATED FILMS WITH PRE-DETERMINABLE HOLE SIZE DISTRIBUTIONS [J].
BAUMEISTER, W ;
SEREDYNSKI, J .
MICRON, 1976, 7 (01) :49-54
[3]   EVAPORATION DURING PREPARATION OF UNSUPPORTED THIN VITRIFIED AQUEOUS LAYERS FOR CRYOELECTRON MICROSCOPY [J].
CYRKLAFF, M ;
ADRIAN, M ;
DUBOCHET, J .
JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1990, 16 (04) :351-355
[4]   ELECTRON-MICROSCOPY OF FROZEN WATER AND AQUEOUS-SOLUTIONS [J].
DUBOCHET, J ;
LEPAULT, J ;
FREEMAN, R ;
BERRIMAN, JA ;
HOMO, JC .
JOURNAL OF MICROSCOPY, 1982, 128 (DEC) :219-237
[5]  
Dubochet J., 1982, ADV OPTICAL ELECTRON, V8, P107
[6]   RF3 induces ribosomal conformational changes responsible for dissociation of class I release factors [J].
Gao, Haixiao ;
Zhou, Zhihong ;
Rawat, Urmila ;
Huang, Chenhui ;
Bouakaz, Lamine ;
Wang, Chernhoe ;
Cheng, Zhihong ;
Liu, Yuying ;
Zavialov, Andrey ;
Gursky, Richard ;
Sanyal, Suparna ;
Ehrenberg, Mans ;
Frank, Joachim ;
Song, Haiwei .
CELL, 2007, 129 (05) :929-941
[7]   Study of the structural dynamics of the E-coli 70S ribosome using real-space refinement [J].
Gao, HX ;
Sengupta, J ;
Valle, M ;
Korostelev, A ;
Eswar, N ;
Stagg, SM ;
Van Roey, P ;
Agrawal, RK ;
Harvey, SC ;
Sali, A ;
Chapman, MS ;
Frank, J .
CELL, 2003, 113 (06) :789-801
[8]   Visualization of macromolecular complexes using cryo-electron microscopy with FEI Tecnai transmission electron microscopes [J].
Grassucci, Robert A. ;
Taylor, Derek ;
Frank, Joachim .
NATURE PROTOCOLS, 2008, 3 (02) :330-339
[9]   Localization and dynamic behavior of ribosomal protein L30e [J].
Halic, M ;
Becker, T ;
Frank, J ;
Spahn, CMT ;
Beckmann, R .
NATURE STRUCTURAL & MOLECULAR BIOLOGY, 2005, 12 (05) :467-468
[10]   THE POTENTIAL AND LIMITATIONS OF NEUTRONS, ELECTRONS AND X-RAYS FOR ATOMIC-RESOLUTION MICROSCOPY OF UNSTAINED BIOLOGICAL MOLECULES [J].
HENDERSON, R .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (02) :171-193